Related Experiment Video
Updated: May 24, 2026

Software for Analysis of Heart Rate and Blood Pressure Time-series Data from the Valsalva Maneuver
Published on: June 27, 2025
Finger photoplethysmography during the Valsalva maneuver reflects left ventricular filling pressure
Harry A Silber1, Jeffrey C Trost, Peter V Johnston
1Division of Cardiology, Department of Medicine, Johns Hopkins University School of Medicine, Baltimore, MD, USA. hsilber@jhmi.edu
Abstract:
It is often challenging to assess cardiac filling pressure clinically. An improved system for detecting or ruling out elevated cardiac filling pressure may help reduce hospitalizations for heart failure. The blood pressure response to the Valsalva maneuver reflects left heart filling pressure, but its underuse clinically may be due in part to lack of continuous blood pressure recording along with lack of standardization of expiratory effort. In this study, we tested whether Valsalva-induced changes in the pulse amplitude of finger photoplethysmography (PPG), a technology already widely available in medical settings, correlate with invasively measured left ventricular end-diastolic pressure (LVEDP). We tested 33 subjects before clinically scheduled cardiac catheterizations. A finger photoplethysmography waveform was recorded during a Valsalva effort of 20 mmHg expiratory pressure sustained for 10 s, an effort most patients can achieve. Pulse amplitude ratio (PAR) was calculated as the PPG waveform amplitude just before release of expiratory effort divided by the waveform amplitude at baseline. PAR was well correlated with LVEDP (r = 0.68; P < 0.0001). For identifying LVEDP > 15 mmHG, PAR > 0.4 was 85% sensitive [95% confidence interval (95CI): 54-97%] and 80% specific (95CI: 56-93%). In conclusion, finger PPG, a technology already ubiquitous in medical centers, may be useful for assessing clinically meaningful categories of left heart filling pressure, using simple analysis of the waveform after a Valsalva maneuver effort that most patients can achieve.
More Related Videos
04:48Noninvasive Determination of Vortex Formation Time Using Transesophageal Echocardiography During Cardiac Surgery
Published on: November 28, 2018
07:09Assessment of Pulmonary Capillary Blood Volume, Membrane Diffusing Capacity, and Intrapulmonary Arteriovenous Anastomoses During Exercise
Published on: February 20, 2017
Related Concept Videos
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above the...
Measurement of Blood Pressure
Cardiovascular System Abnormal Findings I: Inspection and Palpation
Abnormal findings observed during an inspection