Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Total Internal Reflection Fluorescence Microscopy01:05

Total Internal Reflection Fluorescence Microscopy

Total internal reflection fluorescence microscopy or TIRF is an advanced microscopic technique used to visualize fluorophores in samples close to a solid surface with a higher refractive index, such as a glass coverslip. TIRF only allows fluorophores in proximity to the solid surface to be excited. When light from a medium with a lower refractive index (such as air) hits the glass coverslip at a critical angle, the light undergoes total internal reflection stead of passing through the glass.
Computed Tomography01:10

Computed Tomography

Tomography refers to imaging by sections. Computed tomography (CT) is a non-invasive imaging technique that uses computers to analyze several cross-sectional X-rays to reveal minute details about structures in the body.
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Electron Microscope Tomography and Single-particle Reconstruction01:07

Electron Microscope Tomography and Single-particle Reconstruction

Transmission electron microscopy (TEM) can be used to determine the 3D structure of biological samples with the help of techniques such as electron microscope tomography and single-particle reconstruction. While single-particle reconstruction can examine macromolecules and macromolecular complexes in vitro conditions only, tomography permits the study of cell components or small cells in vivo.
Electron Tomography
Electron tomography can be performed either in TEM or STEM (scanning transmission...
Super-resolution Fluorescence Microscopy01:37

Super-resolution Fluorescence Microscopy

Super-resolution fluorescence microscopy (SRFM) provides a better resolution than conventional fluorescence microscopy by reducing the point spread function (PSF). PSF is the light intensity distribution from a point that causes it to appear blurred. Due to PSF, each fluorescing point appears bigger than its actual size, and it is the PSF interference of nearby fluorophores that causes the blurred image. Various approaches to achieving higher resolution through SRFM have recently been developed.
Imaging Studies III: Computed Tomography01:27

Imaging Studies III: Computed Tomography

DefinitionComputed Tomography (CT) of the genitourinary (GU) tract is a non-invasive imaging modality that utilizes X-rays and computer processing to generate detailed cross-sectional images of the urinary system, encompassing the kidneys, ureters, bladder, and adjacent structures such as the adrenal glands.PurposeCT scans of the GU tract serve several diagnostic and therapeutic purposes, including:Diagnosis of Urinary Tract Diseases: Detects kidney stones, tumors, cysts, and congenital...
Confocal Fluorescence Microscopy01:16

Confocal Fluorescence Microscopy

Confocal microscopy is an advanced microscopic technique. The prime advantage of the confocal microscope over other microscopy techniques is its ability to block the out-of-focus light from the illuminated samples using pinholes. It is widely used with fluorescence optics to obtain high-resolution, sharp contrast images. Unlike optical microscopes, confocal microscopes use a focused beam of light laser to scan the entire sample surface at different z-planes. These microscopes are, therefore,...

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Terminal-Group Engineering to Amplify Asymmetric Electronic Interactions in COFs for Enhanced Optoelectronic Performance.

Nano letters·2026
Same author

Structural fatigue failure analysis and lifetime reliability monitoring strategy of the lattice jib in all-terrain cranes.

Scientific reports·2026
Same author

Zero-Contrast Percutaneous Renal Denervation Guided by Multimodal Image Fusion.

JACC. Case reports·2026
Same author

Comment On "Pilot Study of Immediate Lymphatic Reconstruction (ILR) During Lymph Node Dissection for Node-Positive Melanoma: Feasibility, Safety, and Early Outcomes".

Journal of surgical oncology·2026
Same author

SOD1 lactylation impair its enzymatic activity by conformational change to aggravate intervertebral disc degeneration.

Nature communications·2026
Same author

ABSCISIC ACID-INSENSITIVE 5 (ABI5) Orchestrates Seasonal Growth Cessation and Wood Formation Inhibition in <i>Populus tomentosa</i>.

Plants (Basel, Switzerland)·2026

Related Experiment Video

Updated: May 24, 2026

Computed Tomography-guided Time-domain Diffuse Fluorescence Tomography in Small Animals for Localization of Cancer Biomarkers
12:24

Computed Tomography-guided Time-domain Diffuse Fluorescence Tomography in Small Animals for Localization of Cancer Biomarkers

Published on: July 17, 2012

Joint L1 and total variation regularization for fluorescence molecular tomography.

Joyita Dutta1, Sangtae Ahn, Changqing Li

  • 1Signal and Image Processing Institute, Department of Electrical Engineering-Systems, University of Southern California, Los Angeles, CA 90089, USA. Dutta.Joyita@mgh.harvard.edu

Physics in Medicine and Biology
|March 7, 2012
PubMed
Summary

This article introduces a new mathematical method to improve 3D imaging of fluorescent markers in small animals. By combining two specific penalty techniques, the researchers reduce noise and sharpen the boundaries of target areas like tumors, leading to more accurate reconstructions compared to standard approaches.

Keywords:
inverse problemoptical imagingmathematical regularizationbiomarker visualization

Frequently Asked Questions

More Related Videos

Born Normalization for Fluorescence Optical Projection Tomography for Whole Heart Imaging
16:44

Born Normalization for Fluorescence Optical Projection Tomography for Whole Heart Imaging

Published on: June 2, 2009

Correlative Microscopy for 3D Structural Analysis of Dynamic Interactions
13:43

Correlative Microscopy for 3D Structural Analysis of Dynamic Interactions

Published on: June 24, 2013

Related Experiment Videos

Last Updated: May 24, 2026

Computed Tomography-guided Time-domain Diffuse Fluorescence Tomography in Small Animals for Localization of Cancer Biomarkers
12:24

Computed Tomography-guided Time-domain Diffuse Fluorescence Tomography in Small Animals for Localization of Cancer Biomarkers

Published on: July 17, 2012

Born Normalization for Fluorescence Optical Projection Tomography for Whole Heart Imaging
16:44

Born Normalization for Fluorescence Optical Projection Tomography for Whole Heart Imaging

Published on: June 2, 2009

Correlative Microscopy for 3D Structural Analysis of Dynamic Interactions
13:43

Correlative Microscopy for 3D Structural Analysis of Dynamic Interactions

Published on: June 24, 2013

Area of Science:

  • Biomedical engineering research within fluorescence molecular tomography
  • Computational imaging science and mathematical physics

Background:

Fluorescence molecular tomography suffers from significant light scattering and absorption when imaging biological tissues. This physical limitation makes the underlying mathematical reconstruction problem highly unstable and sensitive to noise. Prior research has shown that standard imaging techniques often produce blurred results that fail to capture precise target locations. No prior work had resolved the challenge of balancing signal sparsity with spatial smoothness effectively. Researchers frequently rely on simple penalty functions that spread out the reconstructed signal across the entire volume. That uncertainty drove the need for more sophisticated regularization strategies to constrain the solution space. This gap motivated the development of methods that better reflect the localized nature of fluorescent biomarkers. The current study addresses these limitations by proposing a dual-penalty framework for improved image clarity.

Purpose Of The Study:

The researchers aimed to develop a more effective mathematical approach for reconstructing 3D images in fluorescence molecular tomography. This study addresses the persistent challenge of ill-conditioned inverse problems caused by light scattering in biological tissues. The authors sought to improve upon existing methods that often produce blurred or inaccurate representations of localized fluorescent probes. They specifically targeted the limitations of standard L2 norm penalties, which tend to distribute signals too broadly in space. By introducing a joint regularization framework, the team intended to enforce both sparsity and spatial smoothness simultaneously. This strategy was designed to suppress background noise while maintaining the sharp boundaries of target structures like tumors. The motivation was to provide a more precise tool for visualizing molecular pathways in small animal models. Ultimately, the work strives to enhance the reliability and clarity of tomographic imaging in preclinical research settings.

Main Methods:

The investigators implemented a surrogate-based optimization framework to minimize the joint L1 and total variation penalties. They designed a mouse-shaped phantom to mimic the optical properties of biological tissue. Two distinct fluorescent sources were embedded within this phantom to test the algorithm. The team utilized a 3D imaging setup equipped with a conical mirror for comprehensive surface data collection. An EMCCD camera served as the primary sensor for acquiring the light emission signals. To evaluate performance, the researchers compared their dual-penalty model against L1, L2, and total variation norm approaches. They performed co-registration with CT scans to verify the spatial accuracy of the reconstructed volumes. Finally, the group calculated Dice similarity coefficients to quantify the agreement between the experimental results and the known source locations.

Main Results:

The joint penalty approach achieved superior reconstruction quality compared to the L1, L2, and total variation methods. The authors report that their technique effectively suppresses spurious background signals while preserving the piecewise constant nature of the targets. Quantitative assessment via Dice similarity coefficients confirmed that the dual-penalty model provides more accurate spatial localization of embedded sources. The surrogate-based optimization successfully minimized the joint penalties despite the inherent ill-conditioned nature of the inverse problem. Experimental data from the mouse-shaped phantom showed that the new method maintains sharp boundaries for the fluorescent markers. The researchers observed that the L2 norm penalty alone produced overly spread-out solutions, which the new approach successfully corrected. These findings indicate that the combination of sparsity and smoothness constraints significantly enhances image fidelity. The results demonstrate that the proposed framework is highly effective for visualizing localized molecular targets in complex optical environments.

Conclusions:

The authors demonstrate that their dual-penalty approach outperforms traditional single-penalty methods in reconstructing localized fluorescent sources. Their findings suggest that combining sparsity-enforcing and smoothness-preserving terms yields superior spatial accuracy. This synthesis indicates that the surrogate-based optimization framework effectively handles the complex mathematical requirements of the inverse problem. The researchers observe that their technique successfully suppresses unwanted background noise while maintaining sharp boundaries for embedded targets. Implications of this work include potential improvements in the reliability of small animal imaging for preclinical studies. The study confirms that the proposed method provides a more robust solution compared to existing L1, L2, and total variation benchmarks. The authors conclude that their joint regularization strategy offers a viable path for enhancing the quality of reconstructed molecular images. Future applications may benefit from the increased precision in identifying tumor boundaries and other localized biological features.

The researchers propose a surrogate-based optimization method that combines L1 and total variation penalties. This dual approach simultaneously enforces signal sparsity to remove background noise and preserves spatial smoothness to maintain the piecewise constant nature of the target sources.

The authors utilize an Electron Multiplying Charge-Coupled Device (EMCCD) camera paired with a conical mirror. This hardware configuration enables full-surface viewing, which is necessary for capturing the 3D optical data required for the tomography reconstruction process.

A conical mirror is necessary to achieve full-surface viewing of the phantom. This geometry allows the EMCCD camera to capture light emissions from all angles, which helps mitigate the ill-conditioned nature of the inverse problem caused by tissue light scattering.

The researchers employ both simulated datasets and experimental measurements from a mouse-shaped phantom. These data types are essential for validating the performance of the joint regularization method against established benchmarks like L1, L2, and total variation norms.

The team measures performance using Dice similarity coefficients after co-registering the reconstructed images with Computed Tomography (CT) scans. This metric quantifies the spatial overlap between the reconstructed fluorescent sources and the known ground truth locations within the phantom.

The authors claim that their joint regularization strategy provides a more robust solution than individual penalty methods. They propose that this combined approach is better suited for imaging localized biomarkers, such as those found within tumors, compared to standard techniques.