Assessment of cavopulmonary connections by advanced imaging: value of flat-detector computed tomography
Martin Glöckler1, Andreas Koch, Julia Halbfaß
1Department of Pediatric Cardiology, University Hospital Erlangen, Erlangen, Germany. martin.gloeckler@uk-erlangen.de
Objectives:
To investigate the impact of flat-detector computed tomography on the clinical assessment of patients with cavopulmonary connections, and to evaluate the obtained diagnostic accuracy and supplementary information, as well as the value of overlaid three-dimensional reconstructions on fluoroscopic images during catheter-based interventions.
Methods:
We analysed 31 consecutive patients retrospectively in whom flat-detector computed tomography was used to visualise the cavopulmonary connection. We investigated patients with cavopulmonary connections either early post-operatively (first group), before converting to a total cavopulmonary connection (second group), and patients with failing total cavopulmonary connection (third group). Flat-detector computed tomography based on a single rotational angiography was used to create a three-dimensional vascular model. The clinical value of flat-detector computed tomography was evaluated using standard categories of diagnostic utility. Used contrast volume and radiation exposure were quantified.
Results:
Within 18 months, flat-detector computed tomography was performed in 31 cases with cavopulmonary connections. The median age was 1.9 years (range 0.3-43 years). In the first group, we found anomalies in 4 out of 8 cases, which led to therapeutic or prophylactic procedures; in the second and third groups, we performed interventions in 14 out of 23 cases. The overall clinical value was always rated superior to conventional biplane angiography. The median dose area product was 91.8 microgray square metres (range 33.0-679.3 microgray square metres). The required contrast medium was 2.08 millilitres per kilogram (range 0.66-4.7 millilitres per kilogram).
Conclusion:
Flat-detector computed tomography improves the diagnostic accuracy in cavopulmonary connections and provides additional diagnostic information, which may lead to therapeutic or prophylactic procedures. Overlaid three-dimensional images on fluoroscopy facilitate and provide security for interventions.
More Related Videos
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies for Cardiovascular System V: CT
Imaging Studies III: Computed Tomography
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Pulmonary Embolism II: Diagnostic Studies and Interprofessional Care
Radiological Investigation I: X-ray and CT