Haptic palpation for medical simulation in virtual environments
Related Experiment Video
Updated: May 24, 2026

Creating Virtual-hand and Virtual-face Illusions to Investigate Self-representation
Published on: March 1, 2017
Sebastian Ullrich1, Torsten Kuhlen
1Virtual Reality Group, RWTH Aachen University. s.ullrich@ieee.org
Abstract:
Palpation is a physical examination technique where objects, e.g., organs or body parts, are touched with fingers to determine their size, shape, consistency and location. Many medical procedures utilize palpation as a supplementary interaction technique and it can be therefore considered as an essential basic method. However, palpation is mostly neglected in medical training simulators, with the exception of very specialized simulators that solely focus on palpation, e.g., for manual cancer detection. In this article we propose a novel approach to enable haptic palpation interaction for virtual reality-based medical simulators. The main contribution is an extensive user study conducted with a large group of medical experts. To provide a plausible simulation framework for this user study, we contribute a novel and detailed interaction algorithm for palpation with tissue dragging, which utilizes a multi-object force algorithm to support multiple layers of anatomy and a pulse force algorithm for simulation of an arterial pulse. Furthermore, we propose a modification for an off–the–shelf haptic device by adding a lightweight palpation pad to support a more realistic finger grip configuration for palpation tasks. The user study itself has been conducted on a medical training simulator prototype with a specific procedure from regional anesthesia, which strongly depends on palpation. The prototype utilizes a co-rotational finite-element approach for soft tissue simulation and provides bimanual interaction by combining the aforementioned techniques with needle insertion for the other hand. The results of the user study suggest reasonable face validity of the simulator prototype and in particular validate medical plausibility of the proposed palpation interaction algorithm.
Related Concept Videos
Assessment of the Abdomen III: Palpation
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above the...
Physical Assessment of the Respiratory Tract II: Palpation
Thoracic Palpation
Thoracic palpation detects tenderness, masses, lesions, respiratory excursions, and vocal fremitus. The nurse assesses...

