Precision Implementation of Minimal Erythema Dose (MED) Testing to Assess Individual Variation in Human Inflammatory Response
Published on: October 3, 2019
'Calibration' of our patch test reading technique is necessary
Cecilia Svedman1, Marlene Isaksson, Jonas Björk
1Department of Occupational and Environmental Dermatology, Skåne University Hospital, Malmö, Lund University, 205 02 Malmö, Sweden. Cecilia.Svedman@skane.se
Background:
Patch testing has been used for more than 100 years as the best means to diagnose contact allergy. The increased use of the technique makes standardization of the methodology most important. Progress in the standardization of the patch test technique has been made through guidelines.
Objectives:
To investigate the intra-individual and inter-individual differences in reading of patch tests in order to validate the actual patch test reading when reading is performed according to the same guidelines, and to determine whether information on guidelines actually improves the outcome of the patch test readings
Patients/Materials/Methods:
A patch test course for dermatologists was performed. Volunteers were patch tested with irritants and allergens in different concentrations. The patch test reader did not know what substances had been tested.
Results:
Irritant reactions/doubtful reactions and weak allergic reactions are difficult to differentiate (accordance for these reactions 21%, 19%, and 44%). Information and education have a beneficial effect on results, as shown by an improved kappa value.
Conclusions:
Standardization of patch test reading is important. Information on the classification system resulted in a significant improvement. Interpretation of guidelines should be continuously evaluated.
Related Concept Videos
Instrument Calibration
Analytical Balance Calibration
An analytical balance measures mass and requires regular calibration to...
Glassware Calibration
Volumetric flasks: Volumetric flasks are designed to prepare aqueous solutions of precise volumes accurately with a calibration line on the neck. To calibrate a volumetric flask, it is important to fill it with distilled...
Calibration Curves: Linear Least Squares
For data that follow a straight line, the standard method for fitting is the linear...
Uncertainty in Measurement: Reading Instruments
Errors occurring during blood pressure monitoring
Several factors...