Related Experiment Video
Updated: May 24, 2026

Production of Germ-Free Fast-Growing Broilers from a Commercial Line for Microbiota Studies
Published on: June 18, 2020
Ventilation rates in large commercial layer hen houses with two-year continuous monitoring
1Vegetable Research Centre, Beijing Academy of Agriculture and Forestry Sciences, Beijing, P.R. China.
Abstract:
1. Ventilation controls the indoor environment and is critical for poultry production and welfare. Ventilation is also crucial for assessing aerial pollutant emissions from the poultry industry. Published ventilation data for commercial layer houses have been limited, and are mostly based on short-term studies, mainly because monitoring airflow from large numbers of fans is technically challenging. 2. A two-year continuous ventilation monitoring trial was conducted at two commercial manure belt houses (A and B), each with 250 000 layers and 88 130-cm exhaust fans. All the fans were individually monitored with fan rotational speed sensors or vibration sensors. Differential static pressures across the house walls were also measured. Three fan performance assessment methods were applied periodically to determine fan degradations. Fan models were developed to calculate house ventilations. 3. A total of 693 and 678 complete data days, each containing >16 h of valid ventilation data, were obtained in houses A and B, respectively. The two-year mean ventilation rates of houses A and B were 2·08 and 2·10 m(3) h(-1) hen(-1), corresponding to static pressures of -36·5 and -48·9 Pa, respectively. For monthly mean ventilation, the maximum rates were 4·87 and 5·01 m(3) h(-1) hen(-1) in July 2008, and the minimum were 0·59 and 0·81 m(3) h(-1) hen(-1) in February 2008, for houses A and B, respectively. 4. The two-year mean ventilation rates were similar to those from a survey in Germany and a 6-month study in Indiana, USA, but were much lower than the 8·4 and 6·2 m(3) h(-1) hen(-1) from a study in Italy. The minimum monthly mean ventilation rates were similar to the data obtained in winter in Canada, but were lower than the minimum ventilation suggested in the literature. The lower static pressure in house B required more ventilation energy input. The two houses, although identical, demonstrated differences in indoor environment controls that represented potential to increase ventilation energy efficiency, and reduce carbon footprints and operational costs.
Related Concept Videos
Assessment of Ventilation I: Respiratory Rate
A Ventilation assessment is critical for monitoring a patient's health status. Respiration, one of the most accessible vital signs, provides insights into the function of numerous body systems and can indicate serious health issues, such as brainstem injuries from head trauma.
Critical Guidelines for Assessing Ventilation:
Assessment of Ventilation II: Respiratory Depth and Rhythm
Respiratory depth measures the volume of air inhaled or exhaled during a breath. It can vary from shallow to deep and typically remains consistent when a person is at rest or asleep. Occasionally, individuals will automatically inhale deeply, known as sighing, which inflates the lungs with more air than normal breathing.
To assess respiratory depth, observe the degree of chest excursion or movement:
Respiratory Volumes
Tidal Volume (TV) Tidal volume (TV) is the air inhaled or exhaled in a...
Factors Affecting Pulmonary Ventilation
Alveolar Surface Tension
The alveolar fluid lines the luminal surface of the alveoli and exerts a force called surface tension. This force is caused by the polar water molecules in the liquid being more strongly attracted to each...
Mechanical Ventilation I: Indication and Settings
Respiratory Volumes and Capacities

