Related Experiment Video
Updated: May 24, 2026

The Motivation for Alcohol Reward: Predictors of Progressive-Ratio Intravenous Alcohol Self-Administration in Humans
Published on: April 28, 2022
Breath analyzer screening of emergency department patients suspected of alcohol intoxication
Mustapha Sebbane1, Pierre-Géraud Claret, Riad Jreige
1Département des urgences, Centre Hospitalier Régional Universitaire Lapeyronie, Montpellier, France.
Background:
Acute alcohol intoxication is a frequent cause of emergency department (ED) visits. Evaluating a patient's alcohol intoxication is commonly based on both a physical examination and determination of blood alcohol concentration (BAC).
Objective:
To demonstrate the feasibility and usefulness of using a last-generation infrared breath analyzer as a non-invasive and rapid screening tool for alcohol intoxication in the ED.
Methods:
Adult patients suspected of acute alcohol intoxication were prospectively enrolled over 10 days. Breath alcohol concentrations (BrAC) were measured using a handheld infrared breath analyzer. BAC was determined simultaneously by automated enzymatic analysis of a venous blood sample. The relationship between BAC and BrAC values was examined by both linear regression and Bland-Altman analysis.
Results:
The study included 54 patients (mean age 40±14 years, sex ratio M/F of 3/1). Breath and blood alcohol concentrations ranged from 0 to 1.44 mg/L and from 0 to 4.40 g/L (0-440 mg/dL), respectively. The mean individual BAC/BrAC ratio was 2615±387, 95% confidence interval 2509-2714, which is 30% higher than the legal ratio in France (2000). The correlation between both measurements was excellent: r=0.95 (0.92-0.97). Linear regression revealed BAC=0.026+1.29 (BrAC×2000) and BAC=0.026+0.99 (BrAC×2615). Mean BAC-BrAC differences and limits of agreement were 0.49 g/L [-0.35, 1.34] (or 49 mg/dL [-35, 134] and 0.01 g/L [-0.68, 0.71] (or 1 mg/dL [-68, 71]), for the 2000 and 2615 ratios, respectively.
Conclusion:
The calculated conversion coefficient provided a satisfactory determination of blood alcohol concentration. Breath alcohol testing, using appropriate BAC/BrAC conversion, different from the legal BAC/BrAC, could be a reliable alternative for routine screening and management of alcohol intoxication in the ED.
Related Concept Videos
Assessment of Respiration
Subjective Assessment: Nurses interview the patient to gather information directly during the subjective assessment. It includes questions about the individual's medical history, medications, and symptoms, focusing on past respiratory conditions like asthma or COPD,...
Blood Studies I: ABG and VBG
Arterial Blood Gas (ABG)
Arterial Blood Gas (ABG) studies are crucial for assessing the lungs' ability to supply oxygen and remove carbon dioxide, reflecting the patient's ventilation status. They also help understand the kidneys' capacity to reabsorb or...
Physical Assessment of the Respiratory Tract II: Inspection
Chest Configuration
The chest configuration can...
Respiratory Assessment: Purpose and Indications
Objectives and Importance:
The primary goal of respiratory assessment is to evaluate patients at early risk of clinical deterioration. Since respiratory distress often precedes other signs of declining health, breathing patterns and sounds become a...
SBAR II: Application of SBAR
SBAR Report from a Nurse to a Health Care Provider
S: "Hello, Dr. Smith. This is Jane, RN, from the Med Surg unit. I am calling to tell you about Ms. White in Room 210, who is experiencing increased pain and redness at her incision site. Her recent...
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this principle...

