Nonclinical vaccine safety evaluation: advantages of continuous temperature monitoring using abdominally implanted
Patricia Kaaijk1, Arno A J van der Ark, Geert van Amerongen
1Unit Vaccinology, Centre for Infectious Disease Control, National Institute for Public Health and the Environment, Bilthoven, the Netherlands. Patricia.Kaaijk@rivm.nl
Abstract:
Fever has been reported as the most common adverse event after vaccination in infants and children. For this reason it is important that, prior to clinical testing of a new vaccine, change in body temperature following vaccination is tested carefully in nonclinical animal studies. Since both the timing and the height of the temperature peak after vaccination may differ from vaccine to vaccine, it is important that the time point for body temperature measurement should be chosen on a case-by-case basis with sufficient knowledge of the specific vaccine. In order to determine the best time point for rectal body temperature measurement after vaccination with a new vaccine candidate against N. meningitidis serogroup B, to be applied in a formal Good Laboratory Practice (GLP) toxicology study, miniature temperature data loggers were implanted into the peritoneal cavity of rabbits. The continuous body temperature monitoring appeared to give a complete picture of the entire body temperature kinetics after vaccination. The body temperature peaked at 4 h after vaccination, and this time point was subsequently applied in the toxicology study. Measured body temperature values at the selected time point of 4 h after vaccination were comparable in the continuous temperature setting and in the formal toxicology study, i.e. rectal temperature measurement at one time point. In the present study implanted temperature loggers were successfully used to define an adequate time point to be applied in determining rectal body temperature in a formal GLP toxicology study with a new vaccine candidate.
Related Concept Videos
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Assessing Body Temperature - Rectal
Follow these steps for rectal temperature assessment:
Step 1: Perform hand hygiene and don clean gloves to prevent cross-infection.
Step 2: Position the patient in a side-lying position to better visualize the rectal...
Assessing Body Temperature - Axilla
Step 1: Perform hand hygiene and put on clean gloves to maintain infection control and prevent cross-contamination.
Step 2: Prepare the patient by explaining the procedure to ensure understanding and cooperation. Ensure privacy, expose the axilla, and inform the patient that minimal movement is crucial for an accurate reading.
Step 3: Adjust the patient’s clothing to expose only the axilla. It minimizes...
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's forehead...
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Assessing Body Temperature - Oral
Step 1:
Start by practicing proper hand hygiene to prevent the spread of microorganisms.
Step 2:
Take the thermometer out of the charging unit, switch it on, and wait for the ready sign.
Step 3:
Gently slide the probe cover until a click is heard. This simple action prevents cross-contamination and ensures the correct placement of the probe cover.
Step 4:
Instruct the patient to open their mouth and place...