Related Experiment Video
Updated: May 24, 2026

Spectral and Angle-Resolved Magneto-Optical Characterization of Photonic Nanostructures
Published on: November 21, 2019
Detecting rotating magnetic fields using optically pumped atomic magnetometers for measuring ultra-low-field magnetic
Takenori Oida1, Yosuke Ito, Keigo Kamada
1Department of Electrical Engineering, Graduate School of Engineering, Kyoto University, Kyoto-Daigaku-Katsura, Nishikyo-ku, Kyoto 615-8510, Japan. oida@kuee.kyoto-u.ac.jp
Abstract:
In this paper, we describe the detection of rotating magnetic fields using optically pumped atomic magnetometers (OPAMs) for measuring magnetic resonance (MR) signals. From the results of rotating- and alternating-magnetic-field measurements, we found that to detect a rotating magnetic field with high sensitivity, the rotation direction of the magnetic field to be measured must select the bias-magnetic-field direction of OPAM. In addition, the OPAM sensitivity for rotating magnetic fields should be twice that for alternating magnetic fields. These results indicate that for measuring MR signals, magnetic fields caused by rotating magnetizations can be detected with the sensitivity of 10 fT(rms)/Hz order at 1 kHz using OPAMs.
Related Concept Videos
Atomic Nuclei: Magnetic Resonance
Magnetic Fields
A magnetic field is defined by the force that a charged particle experiences...
Atomic Nuclei: Nuclear Relaxation Processes
Atomic Nuclei: Larmor Precession Frequency
Double Resonance Techniques: Overview
Spin decoupling is usually achieved by...
NMR Spectrometers: Resolution and Error Correction