Related Experiment Video
Updated: May 24, 2026

A Structured Approach to Extubation in Mechanically Ventilated Rats
Published on: July 18, 2025
Effects of mechanical insufflation-exsufflation in preventing respiratory failure after extubation: a randomized
Miguel R Gonçalves1, Teresa Honrado, João Carlos Winck
1Lung Function and Ventilation Unit, Pulmonology Department, University Hospital of São João, Faculty of Medicine, Av. Prof. Hernâni Monteiro, 4200-319 Porto, Portugal. goncalvesmr@gmail.com
Introduction:
Weaning protocols that include noninvasive ventilation (NIV) decrease re-intubation rates and ICU length of stay. However, impaired airway clearance is associated with NIV failure. Mechanical insufflation-exsufflation (MI-E) has been proven to be very effective in patients receiving NIV. We aimed to assess the efficacy of MI-E as part of an extubation protocol.
Method:
Patients with mechanical ventilation (MV) for more than 48 hours with specific inclusion criteria, who successfully tolerated a spontaneous breathing trial (SBT), were randomly allocated before extubation, either for (A) a conventional extubation protocol (control group), or (B) the MI-E extubation protocol (study group). During the postextubation period (48 hours), group A patients received standard medical treatment (SMT), including NIV in case of specific indications, whereas group B received the same postextubation approach plus three daily sessions of mechanical in-exsufflation (MI-E). Reintubation rates, ICU length of stay, and NIV failure rates were analyzed.
Results:
Seventy-five patients (26 women) with a mean age of 61.8 ± 17.3 years were randomized to a control group (n = 40; mean SAPS II, 47.8 ± 17.7) and to a study group (n = 35; mean SAPS II, 45.0 ± 15.0). MV time before enrollment was 9.4 ± 4.8 and 10.5 ± 4.1 days for the control and the study group, respectively. In the 48 hours after extubation, 20 control patients (50%) and 14 study patients (40%) used NIV. Study group patients had a significant lower reintubation rate than did controls; six patients (17%) versus 19 patients (48%), P < 0.05; respectively, and a significantly lower time under MV; 17.8 ± 6.4 versus 11.7 ± 3.5 days; P < 0.05; respectively. Considering only the subgroup of patients that used NIV, the reintubation rates related to NIV failure were significantly lower in the study group when compared with controls; two patients (6%) versus 13 (33%); P < 0.05, respectively. Mean ICU length of stay after extubation was significantly lower in the study group when compared with controls (3.1 ± 2.5 versus 9.8 ± 6.7 days; P < 0.05). No differences were found in the total ICU length of stay.
Conclusion:
Inclusion of MI-E may reduce reintubation rates with consequent reduction in postextubation ICU length of stay. This technique seems to be efficient in improving the efficacy of NIV in this patient population.
Related Concept Videos
Endotracheal Tube Extubation
Procedure
Extubation removes the endotracheal tube (ETT) from the patient on mechanical ventilation. It requires a well-coordinated, multidisciplinary approach involving physicians, nurses, respiratory therapists, and other healthcare professionals.
Endotracheal Intubation II: Nursing Management
1. Nursing Care of Patients Before Intubation
Before the endotracheal intubation procedure, nurses play an essential role in ensuring the process goes smoothly. The nurses must be familiar with intubation...
Endotracheal Intubation I: Procedure
The ET tube comprises various components, including a standard adaptor to attach a bag-valve-mask (BVM) or ventilator, a cuff, a pilot balloon, and radiopaque markings along its length to measure the insertion distance. The tube sizes...
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation (NIPPV)
Mechanical Ventilation I: Indication and Settings
