Related Experiment Video
Updated: May 24, 2026

Endotracheal Intubation Using a Flexible Intubation Endoscope as a Standardized Model for Safe Airway Management in Swine
Published on: August 25, 2022
External laryngeal manipulation does not improve the intubation success rate by novice intubators in a manikin study
Nir Samuel1, Karyn Winkler, Shuny Peled
1Department of Pediatric Emergency, Rambam Health Care Campus, Technion Faculty of Medicine, Haifa 31096, Israel.
Background:
External laryngeal manipulation (ELM) is a technique used in cases of poor glottic view in direct laryngoscopy. Studies investigating ELM in the pediatric population are lacking. The objective of this study was to examine if use of ELM by inexperienced intubators improves the success rate of pediatric intubation.
Methods:
We conducted a randomized, controlled, manikin study comparing intubation using ELM (study subjects) with standard intubation (controls). Study participants were paramedic students. Each participant performed 1 intubation attempt on 3 different pediatric airway manikins, independently. If an optimal Cormack-Lehane glottic view (CLGV) of more than 2 has been obtained, study subjects were previously instructed to perform the intubation using ELM; controls were instructed to continue with standard intubation. Outcome measures were single-attempt intubation success rate, preintubation CLGV, and duration of intubation.
Results:
The study group included 13 subjects who performed 39 intubations. In 19 intubations, CLGV of more than 2 had been obtained; and ELM was used. The control group included 14 subjects who performed 42 intubations. In 20 intubations, CLGV of more than 2 was obtained. Median CLGV score improved from 3.5 before ELM to 2 when ELM was used. However, no difference was found between the groups in intubation success rate (10/19 vs 14/20, P = .43); and the duration of intubation was significantly shorter in controls (25.8 vs 37.8 seconds, P < .007).
Conclusions:
In this pediatric manikin study, ELM performed by novice intubators improved laryngeal view, but lengthened the duration of intubation and did not improve intubation success rate.
Related Concept Videos
Cardiopulmonary Resuscitation V: Advanced Airway Management Techniques
Endotracheal Intubation I: Procedure
The ET tube comprises various components, including a standard adaptor to attach a bag-valve-mask (BVM) or ventilator, a cuff, a pilot balloon, and radiopaque markings along its length to measure the insertion distance. The tube sizes...
Cardiopulmonary Resuscitation II: ACLS Airway Management
Endotracheal Intubation II: Nursing Management
1. Nursing Care of Patients Before Intubation
Before the endotracheal intubation procedure, nurses play an essential role in ensuring the process goes smoothly. The nurses must be familiar with intubation...
Endotracheal Tube Extubation
Procedure