Effects of different therapeutic ultrasound intensities on fracture healing in rats

Chak-Hei Fung1, Wing-Hoi Cheung, Neill M Pounder

  • 1Department of Orthopaedics and Traumatology, The Chinese University of Hong Kong, Shatin, Hong Kong, China.

Insights

Low-intensity pulsed ultrasound (LIPUS) at 30 mW/cm² enhanced fracture healing more than 150 mW/cm². The higher intensity did not improve bone repair in rats.

Area of Science:

  • Biomedical Engineering
  • Regenerative Medicine
  • Orthopedics

Background:

  • Low-intensity pulsed ultrasound (LIPUS) accelerates fracture healing.
  • The effective intensity responsible for LIPUS benefits is debated.
  • Spatial Average Temporal Average (I(SATA)) and Spatial Average Temporal Peak (I(SATP)) intensities are key parameters.

Purpose of the Study:

  • To compare the effects of two LIPUS intensities on fracture healing.
  • To investigate if a higher intensity (150 mW/cm²) enhances healing compared to a standard intensity (30 mW/cm²).

Main Methods:

  • Closed femoral fractures were created in Sprague-Dawley rats.
  • Rats were randomized into control, LIPUS-30 (30 mW/cm² I(SATA)), and LIPUS-150 (150 mW/cm² I(SATA)) groups.
  • Radiographs, microCT, histomorphometry, and biomechanical tests were used for assessment.

Main Results:

  • LIPUS-30 group showed significantly higher low-density bone volume fraction and woven bone percentage compared to control and LIPUS-150 groups.
  • Biomechanical testing revealed significantly higher failure torque in the LIPUS-30 group than control and LIPUS-150 groups at 6 weeks.

Conclusions:

  • LIPUS at 150 mW/cm² I(SATA) did not further enhance fracture healing in rats.
  • The standard intensity of 30 mW/cm² I(SATA) demonstrated superior bone healing outcomes.
  • Findings suggest that higher LIPUS intensity may not be beneficial for fracture repair.