False-negative dual-energy computed tomography in a patient with acute gout
Katrina N Glazebrook1, Sanjeev Kakar, Cristiane M Ida
1Department of Radiology, Mayo Clinic, 200 First St SW, Rochester, MN 55905, USA. glazebrook.katrina@mayo.edu
Abstract:
Gout is a painful inflammatory arthropathy caused by crystallization of monosodium urate within the joints. We present the case of a patient with primary gout who had positive results of joint aspiration and synovial biopsy for monosodium urate crystals in the third metacarpophalangeal joint but false-negative results of dual-energy computed tomography.