Past, present, and future exceedance of critical loads of acidity for surface waters in Finland

Maximilian Posch1, Julian Aherne, Martin Forsius

  • 1Coordination Centre for Effects (CCE), RIVM, P.O. Box 1, NL-3720 BA Bilthoven, The Netherlands. max.posch@rivm.nl

Related Concept Videos

Freshwater Microbial Ecology01:24

Freshwater Microbial Ecology

Freshwater systems such as streams, rivers, and lakes exhibit distinct physical and biological characteristics that influence their microbial communities. These environments are broadly categorized into lotic systems—those with flowing waters like streams and most rivers—and lentic systems, which include still or slow-moving waters such as lakes, ponds, and marshes.In lentic systems, phytoplankton drive primary production, generating autochthonous organic carbon. In contrast, lotic systems...
Acid Mine Drainage01:19

Acid Mine Drainage

Mining activities that disturb sulfide-rich rocks, particularly those containing pyrite (FeS₂), initiate a cascade of geochemical and microbiological processes with serious environmental implications. When exposed to air and water, pyrite undergoes oxidation, releasing sulfate, ultimately forming sulfuric acid and mobilizing heavy metals into surrounding water systems. This phenomenon, known as acid mine drainage (AMD), results in low pH waters laden with toxic elements that threaten aquatic...
Testing Water Quality01:14

Testing Water Quality

When the quality of water for concrete preparation is uncertain, its impact on the setting time of cement and compressive strength of mortar is assessed by comparison with de-ionized or distilled water benchmarks. American Society for Testing and Materials (ASTM) C1602 requires the setting times to be within 90 minutes of the control, British Standard (BS) 3146:1980 allows a 30-minute variance in the initial setting, while British Standards European Norm (BS EN) 1008 specifies initial setting...
Quality of Water01:19

Quality of Water

In concrete preparation, the quality of water is paramount as it affects the strength and durability of the concrete. Potable water is usually preferred; however, it must not have excessive sodium or potassium to prevent compromising the concrete's integrity. Water quality is typically evaluated based on impurities such as dissolved solids, chlorides, and sulfates, and its pH value is ideally between 6 and 8. Even slightly acidic natural water may be acceptable unless it contains harmful...
Mixtures of Acids03:27

Mixtures of Acids

The pH of a solution containing an acid can be determined using its acid dissociation constant and its initial concentration. If a solution contains two different acids, then its pH can be determined using one of several methods depending upon the relative strength of the acids and their dissociation constants.
A Mixture of a Strong Acid and a Weak Acid
In a mixture of a strong acid and a weak acid, the strong acid dissociates completely and becomes a source of almost all the hydronium ions...
Solution Composition During Acid/Base Titrations01:17

Solution Composition During Acid/Base Titrations

The titration of a weak acid with a strong base results in the formation of water and the conjugate base of the acid. For instance, titrating acetic acid with sodium hydroxide leads to the formation of water and sodium acetate. A solution of acetic acid and sodium acetate constitutes a buffer whose relative concentration at different stages of the titration is indicated by the α values, which represent percentages of the weak acid and its conjugate base.
The α0 and α1 values represent the...