Degradation of organics in reverse osmosis concentrate by electro-Fenton process
Minghua Zhou1, Qingqing Tan, Qian Wang
1Key Laboratory of Pollution Process and Environmental Criteria, Ministry of Education, College of Environmental Science and Engineering, Nankai University, Tianjin 300071, China. zhoumh@nankai.edu.cn
Abstract:
The present work studied, for the first time, the removal of organic pollutants from a high-salinity reverse osmosis (RO) concentrate by electro-Fenton approach using a graphite-felt as cathode. To gain insights into the process, the in situ generation of hydrogen peroxide was also investigated. The COD removal efficiency and energy consumption were optimized by investigating the effects of some important operating parameters such as ferric ion concentration, initial pH and cathodic potential. Under the conditions of cathodic potential at -0.72V and Fe(3+) concentration 0.2mM, more than 62% COD could be removed in 3h treatment, meeting the local wastewater discharge requirement (COD <50mg/L). It confirmed the feasibility of electro-Fenton process for the treatment of RO concentrate accounting for its cost-effectiveness in wide pH ranges.