Related Experiment Video
Updated: May 23, 2026

3D Planning and Printing of Patient Specific Implants for Reconstruction of Bony Defects
Published on: August 4, 2020
Mandibular reconstruction using AO/ASIF stainless steel reconstruction plate: a retrospective study of 36 cases
G Harsha1, S Ganesh Kumar Reddy, Sunil Talasila
1Department of Oral and Maxillofacial Surgery, MNR Dental College, Sangareddy, Hyderabad, Andhra Pradesh, India. dentiharsha@yahoo.com
Aim:
The study was aimed at esthetic and functional results as well as patient tolerance after reconstruction with reconstruction plate. The follow-up ranged from 1 to 4 years.
Materials And Methods:
A retrospective study of 36 patients who had mandibular reconstruction with AO/ASIF stainless steel reconstruction plates after oncologic resection was evaluated. The indications and postoperative outcomes were studied.
Results:
At the end of study, 24 of 36 patients (67%) still had the plate in place. Around three (8%) plates were fractured. Nine (25%) plates got exposed leading to surgical intervention. Surgical results were satisfying, particularly when looking at delayed healing or long-term tolerance. Esthetic (79% rated results as good or acceptable) and functional results of this reconstruction were satisfying.
Conclusion:
We conclude by saying that reconstruction plate provides a solution for safe and rapid mandibular reconstruction for patients with poor prognosis or poor condition. This method also preserves the possibility of secondary reconstruction.
Clinical Significance:
The reconstruction plate may be a good clinical choice for safe and rapid mandibular reconstruction.