Related Experiment Video
Updated: May 23, 2026

Upper-extremity Approach for Secondary Access in Transfemoral Transcatheter Aortic Valve Implantation
Published on: August 8, 2025
Venous spasm during contrast-guided axillary vein puncture for pacemaker or defibrillator lead implantation
1Department of Cardiology, The First People's Hospital of Hangzhou, 261# Huansha Road, Hangzhou 310000, China. duanxu410@yahoo.com.cn
Aims:
Contrast-guided axillary vein puncture is commonly used for pacemaker or defibrillator lead implantation. Venous spasm during contrast-guided axillary vein puncture has been reported rarely. We investigated the incidence of venous spasm during contrast-guided axillary vein puncture and the impact of venous spasm on axillary vein puncture.
Methods And Results:
Seventy-four consecutive patients referred for contrast-guided axillary vein puncture for pacemaker or defibrillator implantation were included in the study. The puncture was guided by fluoroscopy and the venogram of axillary vein. After the success of puncture, the venography was taken again. When the puncture could not be successful up to 3 min, the second venography was taken and the puncture was guided by the second venogram. The degree of venous spasm was evaluated by the reduction in the lumen calibre of the axillary vein after puncture. Mild venous spasm and severe venous spasm were defined as a reduction in the lumen calibre of 50-90 and ≥ 90%, respectively. The success rate of axillary vein puncture within 3 min was 87.8%, and the total success rate was 95.9%. Mild venous spasm occurred in 22 patients (29.7%) and severe venous spasm occurred in 6 patients (8.1%). Severe venous spasm occurred in all the three patients with a failed puncture. Severe venous spasm was independently negatively correlated with both success rate within 3 min and total success rate.
Conclusion:
Venous spasm is not a rare phenomenon during the contrast-guided puncture of axillary vein and it has an important negative impact on the puncture.
More Related Videos
10:46Non-fluoroscopic Catheter Tracking for Fluoroscopy Reduction in Interventional Electrophysiology
Published on: May 26, 2015
12:45Benefits of Cardiac Resynchronization Therapy in an Asynchronous Heart Failure Model Induced by Left Bundle Branch Ablation and Rapid Pacing
Published on: December 11, 2017
Related Concept Videos
Local Anesthetics: Clinical Application as Intravenous Regional Anesthesia
One of the advantages of...
Cardiac Catheterization IV: Nursing Management
Vascular Spasm
Cardiac Catheterization II: Right Heart Catheterization
Cardiac Catheterization I: Pre-Procedure Overview
Venous Thrombosis II: Clinical Manifestations and Diagnostic Studies