Published on: October 16, 2013
MedJet--a new CO2-based disposable cleaning device allows safe and effective bowel cleansing during colonoscopy: a
R Kiesslich1, N Schuster, A Hoffman
1I. Med. Klinik, Universitätsmedizin Mainz, Langenbeckstrasse 1, Mainz, Germany. kiesslich@uni-mainz.de
Background And Study Aims:
Complete bowel cleansing is mandatory for effective colon cancer screening and surveillance. The aim of the current pilot study, which was conducted in humans, was to test the safety and efficiency of a newly developed disposable cleaning device, the MedJet, for intraprocedural bowel cleansing.
Patients And Methods:
Patients with screening or surveillance colonoscopy after previous polypectomy were included. The colonoscope was first inserted to the cecum and the overall cleansing was assessed according to the Ottawa scale. The MedJet device was used if colon cleansing had been incomplete. The MedJet catheter was passed over the working channel of the colonoscope and the colon was cleaned during withdrawal. The MedJet device delivered controlled jets comprising compressed CO2 and minimal amounts of sterile water, which allowed disintegration and removal of residual stool. The efficiency of cleaning was assessed according to the Boston scale.
Results:
A total of 32 patients (16 female; mean age 61 years) were treated with the device. No device-related adverse or serious adverse events were noted. MedJet application during withdrawal provided effective and significant improvement in bowel cleansing (P = 0.005). Furthermore, 18 adenomas and 1 colon cancer, which were hidden behind stool remnants, could be identified in 11 patients following use of the MedJet device. However, the withdrawal times were prolonged (11.4±6.0 minutes) due to the additional cleaning procedure. All patients tolerated the procedure well.
Conclusions:
The new MedJet device enabled highly effective and safe bowel cleansing during colonoscopy. The catheter-based system was easy to use and CO2 was applied for cleansing. The procedure was well tolerated by patients.
More Related Videos
06:28E-Patient Counseling Trial (E-PACO): Computer Based Education versus Nurse Counseling for Patients to Prepare for Colonoscopy
Published on: August 1, 2019
03:43Structured Approach to Colonoscopy Technique Optimization: A Single-Center Experience with Novice Endoscopists
Published on: July 11, 2025
Related Concept Videos
Imaging Studies III: Gastrointestinal Motility Studies and Virtual Colonoscopy
Radionuclide Testing
Radionuclide testing is a sophisticated medical technique for assessing gastrointestinal motility. It focuses on gastric emptying and colonic transit time. Radioactive markers track the movement of food through the digestive system, providing insights into gastrointestinal disorders.
In gastric emptying studies, a meal's liquid and solid...
Endoscopic Procedures II: Colonoscopy
Endoscopic Procedures IV: Sigmoidoscopy and Laproscopy
Sigmoidoscopy
Sigmoidoscopy is a diagnostic procedure that uses a flexible sigmoidoscope equipped with a light source and camera to examine the rectum and sigmoid colon. The procedure involves inserting the tube through the anus...
Endoscopic Procedures III: Video Capsule Endoscopy
Lower GI Series: Barium Enema
Procedure Details
The examination begins by inserting a lubricated rectal tube into the patient's rectum to administer a radiopaque barium solution. The barium flow is carefully...