A Structured Approach to Extubation in Mechanically Ventilated Rats
Published on: July 18, 2025
Prediction of extubation failure in medical intensive care unit patients
Bernd Saugel1, Philipp Rakette, Alexander Hapfelmeier
1II Medizinische Klinik und Poliklinik, Klinikum rechts der Isar der Technischen Universität München, Ismaninger Strasse 22, D-81675 München, Germany. bcs.muc@gmx.de
Purpose:
The purpose of this study was to evaluate prediction factors for extubation failure (need for reintubation within 48 hours) in medical intensive care unit patients.
Materials And Methods:
Sixty-one patients extubated after mechanical ventilation for more than 48 hours were included in the study. A retrospective analysis of medical records and a prospectively maintained database on respiratory parameters was conducted.
Results:
Low serum anion gap (P = .001), low serum anion gap corrected for serum albumin (P = .010), and low arterial partial pressure of oxygen (Pao(2))/fraction of inspired oxygen (Fio(2)) ratio (P = .032) were significantly associated with extubation failure. Binary logistic regression analysis revealed low uncorrected and corrected serum anion gap (P = .006 and P = .025, respectively; odds ratio, 0.59 for both) and low Pao(2)/Fio(2) ratio (P = .038; odds ratio, 0.99) as risk factors for extubation failure. Regarding extubation failure, receiver operating characteristic curve (ROC) analysis demonstrated good predictive capabilities of serum anion gap (ROC area under the curve, 0.835; P = .004; cutoff, 7.7 mEq/L; sensitivity, 70.4%; specificity, 85.7%) and corrected serum anion gap (ROC area under the curve, 0.808; P = .009; cutoff, 8.8 mEq/L; sensitivity, 87.5%; specificity, 71.4%). A significantly higher risk for extubation failure was observed in patients with serum anion gap 5.2 mEq/L or less (relative risk, 8.8; 95% confidence interval, 2.4-32.4; P = .004) and corrected serum anion gap 8.6 mEq/L or less (relative risk, 10.0; 95% confidence interval, 2.2-44.9; P = .004).
Conclusions:
Low preextubation serum anion gap values and low preextubation Pao(2)/Fio(2) ratio might help to predict extubation failure in medical intensive care unit patients.
Related Concept Videos
Endotracheal Tube Extubation
Procedure
Extubation removes the endotracheal tube (ETT) from the patient on mechanical ventilation. It requires a well-coordinated, multidisciplinary approach involving physicians, nurses, respiratory therapists, and other healthcare professionals.
Endotracheal Intubation II: Nursing Management
1. Nursing Care of Patients Before Intubation
Before the endotracheal intubation procedure, nurses play an essential role in ensuring the process goes smoothly. The nurses must be familiar with intubation...
Endotracheal Intubation I: Procedure
The ET tube comprises various components, including a standard adaptor to attach a bag-valve-mask (BVM) or ventilator, a cuff, a pilot balloon, and radiopaque markings along its length to measure the insertion distance. The tube sizes...
Acute Respiratory Failure-III
Acute Respiratory Failure-V
Ensure that patients are monitored continuously for their response to therapy, including changes in...
Acute Respiratory Failure-II
The underlying physiological abnormalities that contribute to hypoxemic respiratory failure include: