Purpose:
To estimate the possible radiation dose to other individuals from patients treated with yttrium-90 ((90)Y).
Materials And Methods:
Dosimetry data were analyzed after 143 consecutive administrations of (90)Y (124 resin, 19 glass) in 86 patients. External radiation exposure levels from patients were measured immediately after infusion. Total effective dose equivalent (TEDE) to maximally exposed individuals was calculated based on total body residence time and measured dose rate. These values were compared to Nuclear Regulatory Commission (NRC) regulations (maximum, 1 mSv) and other potential guidelines for caregivers, extensive caregivers, or pregnant contacts.
Results:
Mean administered activity for resin microspheres was 0.71 GBq ± 0.35 (range, 0.07-1.6GBq). Mean TEDE dose to the maximally exposed contact was 0.03 mSv (range, 0.0005-0.16 mSv). For glass microspheres, mean administered activity was 2.8 GBq ± 1.5 (range, 0.37-5.14 GBq). Mean TEDE dose to the maximally exposed contact was 0.06 mSv (range, 0.0023-0.23 mSv). All (90)Y treatments were within current NRC regulations for release without instructions. One, three, and one infusion were beyond potential thresholds for caregivers, extensive caregivers, or pregnant contacts, respectively. For any contact scenario, release without instruction was appropriate when administered activity was less than 3 GBq.
Conclusions:
All patients treated with (90)Y hepatic radioembolization to a maximum administered activity of 5.14 GBq and maximum dose rate of 10 uSv/h were releasable without contact restrictions according to the NRC contact scenario. Patients who receive more than 3 GBq during infusion may require dose rate measurement if more restrictive contact scenarios are considered.
Related Concept Videos
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Transmission-based Precautions II: Airborne and Protective Environment
Airborne precautions:
Use airborne precautions when treating patients known or suspected to have diseases that spread through the air—for example, tuberculosis or measles. These organisms are present in smaller droplets expelled by an infected person and...
Transmission-based Precautions I: Contact, Enteric, and Droplets
Contact Precautions:
Contact precautions are the measures taken to prevent the transmission of infectious agents, especially epidemiologically important microorganisms such as MRSA or influenza, primarily transmitted through direct or indirect contact with an...
Radiological Investigation I: X-ray and CT
Standard Precaution
Hand hygiene is the most crucial means to prevent the transmission of disease. Employers are legally required to provide their workers with personal protective equipment (PPE) to minimize exposure or contact with...