Simultaneous Recording of Electroretinography and Visual Evoked Potentials in Anesthetized Rats
Published on: July 1, 2016
Contrast-response functions of the multifocal steady-state VEP (MSV)
S N Abdullah1, Vaegan, M Y Boon
1School of Optometry and Vision Science, University of New South Wales, Sydney, Australia.
Objectives:
To measure contrast-response functions (CRFs) for 9 visual field (VF) regions and nonlinear interactions between regions using a multifocal steady-state VEP (MSV).
Methods:
Ten normal adults were tested (51.7 ± 16.9 yr, 5 females). Stimuli resembling those of the Frequency Doubling Technology (FDT) perimeter were presented in 9 VF regions simultaneously, which were modulated at incommensurate temporal frequencies (mean 19.7 Hz). Responses were recorded to 11 contrasts from 3% to 89%, using 8 scalp electrodes. Two repeats of a 20s duration stimulus were averaged for each contrast.
Results:
The CRFs were log-linear except for a depression near 7% contrast (p=0.0008), which was prominent in the central VF. The effects of VF region, stimulus frequency and recording electrode were significant (all p<0.016). Significant responses at frequencies corresponding to interactions between VF regions also appeared. Electrodes that were best for the interactions and second harmonic responses differed, suggesting different cortical sources.
Conclusions:
Despite short recording durations the saturating CRFs meant that significant responses could be measured to low contrasts, and be distinguished from nonlinear interactions.
Significance:
Recording MSVs to low contrast FDT-like stimuli might be useful for quantifying damage by glaucoma and other visual disorders.
Related Concept Videos
Color Vision
Anatomy of the Eyeball
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...