Identification of the Source of Secreted Proteins in the Kidney by Brefeldin A Injection
Published on: November 10, 2021
[Comparison of different methods for PAS staining of renal biopsy tissue sections]
Zhan-Mei Zhou1, Fang Yang, Wei Cao
1Department of Nephrology, Nanfang Hospital, Southern Medical University, Guangdong Provincial Institute of Nephrology, Guangzhou 510515, China.
Objective:
To compare the performance of a modified PAS staining, traditional PAS staining, Lyon's PAS staining, and Tsunahico Watanabe staining for staining sections of renal biopsy tissue.
Methods:
The sections of the renal biopsy tissue were stained with the 4 methods and their staining performance was compared.
Results:
The modified PAS staining method produced a better contrast and a higher resolution and showed a greater stability after repeated use than the other 3 methods for staining the renal tissue sections (P<0.05).
Conclusion:
The modified PAS staining method shows a better applicability than the other 3 PAS methods for staining sections of renal biopsy tissue.