Total correction in tetralogy of Fallot with anomalous major coronary artery: an alternative method to conduit use
1Department of Cardiovascular Surgery, Baskent University Hospital, Istanbul, Turkey. bsaritas@hotmail.com
Introduction:
A coronary artery anomaly precludes the use of a trans-annular patch in right ventricular outflow tract (RVOT) reconstruction. Herein we present three patients with coronary artery anomalies who underwent total corrective operations without using a conduit.
Methods:
Between 2007 and 2010, 84 patients with tetralogy of Fallot (TOF) were operated on. Nine (9.4%) of them had a coronary artery anomaly. Three (3.1%) of the patients were operated on using the double-outflow technique and two had a Blalock-Taussig shunt before the total corrective operation. In two patients, the left anterior descending artery (LAD) and in one, the right coronary artery (RCA) crossed the RVOT.
Results:
Postoperatively, the right-to-left ventricular pressure ratios were 0.45, 0.59 and 0.60 after cardiopulmonary bypass. No gradient was detected in the RVOT in postoperative echocardiographical measurements (< 15 mmHg gradient). In all three patients, there were moderate pulmonary insufficiencies. All were discharged home on the sixth day postoperatively. Mean follow-up duration was 9.8 ± 8 months. In the follow up of all three patients, there were moderate pulmonary insufficienciencies but no right ventricular dysfunction.
Conclusion:
The 'double-outflow' technique is appropriate for TOF patients with a major coronary artery anomaly since it can easily be performed without the need of a conduit.