Measurement of the CP-violating phase ϕ(s) in the decay B(s)(0) J/ψϕ

R Aaij1, C Abellan Beteta, B Adeva

  • 1Nikhef National Institute for Subatomic Physics, Amsterdam, The Netherlands.

Related Concept Videos

Phasors01:12

Phasors

Phasors are a powerful mathematical tool used to analyze alternating current (AC) circuits. They provide a complex number representation of sinusoids, with the magnitude of the phasor equating to the amplitude of the sinusoid and the angle of the phasor representing the phase measured from the positive x-axis.
One of the significant benefits of using phasors is that they simplify the analysis of AC circuits by eliminating the time dependence of the current and voltage. This transformation...
Transfer function and Bode Plots-II01:23

Transfer function and Bode Plots-II

In the standard form, the transfer function is shown in constant gain, poles/zeros at origin, simple poles/zeros, and quadratic poles/zeros; each contributing uniquely to the system's overall response. The term represents the magnitude of the simple zero:
Phasor Arithmetics01:13

Phasor Arithmetics

Phasors and their corresponding sinusoids are interrelated, offering unique insights into the behavior of alternating current (AC) circuits. One way to understand this relationship is through the operations of differentiation and integration in both the time and phasor domains.
When the derivative of a sinusoid is taken in the time domain, it transforms into its corresponding phasor multiplied by j-omega (jω) in the phasor domain, where j is the imaginary unit, and ω is the angular frequency.
Graphical and Analytic Representation of Sinusoids01:20

Graphical and Analytic Representation of Sinusoids

Analyzing two sinusoidal voltages with equal amplitude and period but different phases on an oscilloscope, an instrument used to display and analyze waveforms, involves a three-step process.
The first step is measuring the peak-to-peak value, which is twice the amplitude of the sinusoid. This provides information about the maximum voltage swing of the waveform.
Secondly, the period and angular frequency are determined. The period is the time taken for one complete cycle of the waveform, while...
Time and frequency -Domain Interpretation of Phase-lag Control01:21

Time and frequency -Domain Interpretation of Phase-lag Control

Phase-lag controllers are widely used in control systems to improve stability and reduce steady-state errors. A dimmer switch controlling the brightness of a light bulb serves as a practical example of phase-lag control, gradually adjusting the bulb's brightness. Mathematically, phase-lag control or low-pass filtering is represented when the factor 'a' is less than 1.
Phase-lag controllers do not place a pole at zero, but instead influence the steady-state error by amplifying any finite,...
The Phase Rule01:20

The Phase Rule

The phase rule describes the relationship between the variance (degrees of freedom), the number of components, and the number of phases in a system at equilibrium.Variance is a concept that denotes the number of independent intensive properties (properties are those that do not depend on the amount of material in the system), such as temperature, pressure, and composition, that can be altered without impacting the number of phases in equilibrium.In a single-component system, such as pure water,...