Electrostatic polarization is critical for the strong binding in streptavidin-biotin system

Ye Mei1, Yong L Li, Juan Zeng

  • 1State Key Laboratory of Precision Spectroscopy, Department of Physics, Institute of Theoretical and Computational Science, East China Normal University, Shanghai 200062, China. ymei@phy.ecnu.edu.cn

Related Concept Videos

Ligand Binding Sites02:40

Ligand Binding Sites

Proteins are dynamic macromolecules that carry out a wide variety of essential processes; however, the activities of most proteins depend on their interactions with other molecules or ions, known as ligands.
Protein-ligand interactions are quite specific; even though numerous potential ligands surround a cellular protein at any given time, only a particular ligand can bind to that protein. Moreover, a ligand binds only to a dedicated area on the surface of the protein, known as the...
The Equilibrium Binding Constant and Binding Strength02:18

The Equilibrium Binding Constant and Binding Strength

The equilibrium binding constant (Kb) quantifies the strength of a protein-ligand interaction. Kb can be calculated as follows when the reaction is at equilibrium:
The Equilibrium Binding Constant and Binding Strength02:18

The Equilibrium Binding Constant and Binding Strength

The equilibrium binding constant (Kb) quantifies the strength of a protein-ligand interaction. Kb can be calculated as follows when the reaction is at equilibrium:
Theory of Strong Electrolytes01:23

Theory of Strong Electrolytes

The interionic forces of the strong electrolytes depend on the solvent's dielectric constant, which is the ability of a solvent to store electrical energy, based on its polarizability. and the solution's concentration. In high-dielectric solvents and in dilute solutions, weak electrostatic forces keep ions apart. However, in low-dielectric solvents or concentrated solutions, stronger interionic forces may cause ions to pair up as ionic doublets despite being fully ionized. The theory of strong...
Capillary Electrophoresis: Instrumentation01:20

Capillary Electrophoresis: Instrumentation

Capillary electrophoresis instrumentation typically consists of several key components. A high-voltage power supply generates the electric field necessary for the separation by connecting to an anode (the positively charged electrode) and a cathode (the negatively charged electrode) located in buffer reservoirs at each end of the capillary tube. The system includes a sample vial, a fused silica capillary tube coated with polyimide for mechanical strength through which the sample components...
Noncovalent Attractions in Biomolecules02:35

Noncovalent Attractions in Biomolecules

Noncovalent attractions are associations within and between molecules that influence the shape and structural stability of complexes. These interactions differ from covalent bonding in that they do not involve sharing of electrons.
Four types of noncovalent interactions are hydrogen bonds, van der Waals forces, ionic bonds, and hydrophobic interactions.
Hydrogen bonding results from the electrostatic attraction of a hydrogen atom covalently bonded to a strong-electronegative atom like oxygen,...