Related Experiment Video
Updated: May 23, 2026

Trabecular Meshwork Response to Pressure Elevation in the Living Human Eye
Published on: June 20, 2015
Eye vessel compliance as a function of intraocular and arterial pressure and eye compliance
Adan Villamarin1, Sylvain Roy, Nikolaos Stergiopulos
1Swiss Federal Institute of Technology, Lausanne, Switzerland. adan.villamarin@epfl.ch
Purpose:
The purpose of our study is to develop and validate a methodology to measure the compliance of the vascular network in the eye using biomechanical parameters, namely arterial pressure, intraocular pressure (IOP), and ocular compliance of the eyeball (OC).
Methods:
In vitro experiments were conducted on 6 freshly enucleated rabbit eyes. An inflatable catheter was inserted in the posterior chamber. The balloon was inflated and its volume changed periodically at a rate of 1-2 Hz, yielding variations in the intraocular volume; thus, emulating the volume pulsations of the vascular network in the eye. The IOP was measured continuously with a pressure transducer and the OC was calculated using the outflow facility. The compliance of the balloon, mimicking the compliance of the vascular network, was estimated indirectly from the measurements of IOP, balloon pressure, and OC. The estimated balloon compliance was compared to direct estimates of balloon compliance, based on the balloon pressure-volume curve. In vivo study included 5 white New-Zealand rabbits. The method to estimate the vascular compliance of the eye was tested under normal conditions and after administration of norepinephrine, which induced a vasoconstriction leading to reduction in vascular compliance.
Results:
In vitro comparison of direct versus indirect estimates of compliance showed a difference that was not significant (0.075 vs. 0.077 μL/mm Hg, P = 0.86). Results from the in vivo study indicated that norepinephrine significantly increased the arterial pulse pressure amplitude, while compliance of vascular network of the eye decreased from 0.18 ± 0.12 to 0.10 ± 0.08 μL/mm Hg (P = 0.001).
Conclusions:
The eye vascular compliance can be predicted using the IOP, arterial pressure, and OC of the eyeball.
Related Concept Videos
Glaucoma: Overview
Accessory Structures of the Eye
Open Angle Glaucoma: Treatment
Drugs such as carbonic anhydrase inhibitors, α2- and...
Autoregulation of Blood Flow
Chemical Signaling in Autoregulation
Chemical signaling operates at the precapillary sphincter level, inciting either contraction or relaxation.
Angle Closure Glaucoma: Treatment
Vascular Resistance
The primary determinants of vascular resistance are vessel diameter, blood viscosity, and vessel length. Among these, vessel diameter plays the most significant role due to the fourth power relationship described by...