Related Experiment Video
Updated: Feb 11, 2026

Anesthesia and Intubation of Preadolescent Mouse Pups for Cardiothoracic Surgery
Published on: June 2, 2022
Oxygen and anesthesia: what lung do we deliver to the post-operative ward?
1Department of Medical Sciences, Clinical Physiology, University Hospital, Uppsala, Sweden.
Abstract:
Anesthesia is safe in most patients. However, anesthetics reduce functional residual capacity (FRC) and promote airway closure. Oxygen is breathed during the induction of anesthesia, and increased concentration of oxygen (O(2) ) is given during the surgery to reduce the risk of hypoxemia. However, oxygen is rapidly adsorbed behind closed airways, causing lung collapse (atelectasis) and shunt. Atelectasis may be a locus for infection and may cause pneumonia. Measures to prevent atelectasis and possibly reduce post-operative pulmonary complications are based on moderate use of oxygen and preservation or restoration of FRC. Pre-oxygenation with 100% O(2) causes atelectasis and should be followed by a recruitment maneuver (inflation to an airway pressure of 40 cm H(2) O for 10 s and to higher airway pressures in patients with reduced abdominal compliance (obese and patients with abdominal disorders). Pre-oxygenation with 80% O(2) may be sufficient in most patients with no anticipated difficulty in managing the airway, but time to hypoxemia during apnea decreases from mean 7 to 5 min. An alternative, possibly challenging, procedure is induction of anesthesia with continuous positive airway pressure/positive end-expiratory pressure to prevent fall in FRC enabling use of 100% O(2) . A continuous PEEP of 7-10 cm H(2) O may not necessarily improve oxygenation but should keep the lung open until the end of anesthesia. Inspired oxygen concentration of 30-40%, or even less, should suffice if the lung is kept open. The goal of the anesthetic regime should be to deliver a patient with no atelectasis to the post-operative ward and to keep the lung open.
Related Concept Videos
Cardiomyopathy VII: Pre and Post Operative Nursing Management
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Oxygen Delivering System I: Nasal Cannula and Face Mask
Nasal Cannula
A nasal cannula is a lightweight tube split at one end into two prongs and placed in the nostrils. It is typically used to deliver low to medium levels of oxygen.
Suggested flow rate: The suggested flow rate for a nasal cannula typically ranges between 1 and 6 L/min.
Oxygen percentage setting:...
Oxygen Delivering System III: Tracheostomy and T-piece
Tracheostomy
A tracheostomy is a surgically created opening (stoma) in the anterior part of the trachea. It is used to establish a patient airway, bypass an upper airway obstruction, simplify the removal of secretions, permit long-term...
General Anesthesia: Overview
General anesthesia induces unconsciousness in the whole body, while the others target specific areas or sensations. It is administered to minimize adverse effects, maintain...
Stages of General Anesthesia

