C-arm-Free Simultaneous OLIF51 and Percutaneous Pedicle Screw Fixation in a Single Lateral Position
12:25

C-arm-Free Simultaneous OLIF51 and Percutaneous Pedicle Screw Fixation in a Single Lateral Position

Published on: September 16, 2022

[Hardware removal after pelvic ring injury].

F M Stuby1, C E Gonser, H C Baron

  • 1Klinik für Unfall- und Wiederherstellungschirurgie, Berufsgenossenschaftliche Unfallklinik Tübingen, Eberhard Karls-Universität Tübingen, Schnarrenbergstraße 95, 72076, Tübingen, Deutschland.

Der Unfallchirurg
|April 6, 2012
PubMed
Summary
This summary is machine-generated.

Related Concept Videos

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Return to initial work and fulfillment of expectations in patients with complex proximal tibial fracture is influenced by physical workload and workers´ compensation status.

Injury·2025
Same author

[Imaging examination procedures, navigation and minimally invasive procedures in acetabular surgery].

Unfallchirurgie (Heidelberg, Germany)·2023
Same author

The Association between Constitutional Knee Alignment and the Horizontal Orientation of the Ankle Joint Line.

Acta chirurgiae orthopaedicae et traumatologiae Cechoslovaca·2022
Same author

Single-stage total hip arthroplasty after failed fixation of proximal femoral fractures: an increased risk for periprosthetic joint infections?

Archives of orthopaedic and trauma surgery·2021
Same author

Management of proximal femur fractures in the elderly: current concepts and treatment options.

European journal of medical research·2021
Same author

[Periprosthetic fractures of the acetabulum: osteosynthesis].

Der Chirurg; Zeitschrift fur alle Gebiete der operativen Medizen·2020

Indications for pelvic ring hardware removal require strict definition. Removal is indicated for complications like infection or malpositioning, but elective removal needs careful risk-benefit assessment.

Area of Science:

  • Orthopedic surgery
  • Traumatology

Background:

  • Pelvic ring fractures are rare but can necessitate surgical fixation.
  • Minimally invasive sacroiliac screw fixation is increasingly used for dorsal pelvic ring injuries.
  • Anterior pelvic ring fixation involves plates, screws, or external fixation.

Purpose of the Study:

  • To define strict indications for hardware removal in pelvic ring fractures.
  • To evaluate the risks and benefits of hardware removal in specific patient cohorts.

Main Methods:

  • Retrospective analysis of 80 patients with pelvic ring B- or C-type injuries over 8 years.
  • Review of indications for hardware removal based on clinical outcomes and complications.

Main Results:

More Related Videos

A Suture Technique for Ruptured Annulus Fibrosus Following Decompression Under Percutaneous Transforaminal Endoscopic Discectomy
03:24

A Suture Technique for Ruptured Annulus Fibrosus Following Decompression Under Percutaneous Transforaminal Endoscopic Discectomy

Published on: January 26, 2024

Related Experiment Videos

Last Updated: May 23, 2026

C-arm-Free Simultaneous OLIF51 and Percutaneous Pedicle Screw Fixation in a Single Lateral Position
12:25

C-arm-Free Simultaneous OLIF51 and Percutaneous Pedicle Screw Fixation in a Single Lateral Position

Published on: September 16, 2022

A Suture Technique for Ruptured Annulus Fibrosus Following Decompression Under Percutaneous Transforaminal Endoscopic Discectomy
03:24

A Suture Technique for Ruptured Annulus Fibrosus Following Decompression Under Percutaneous Transforaminal Endoscopic Discectomy

Published on: January 26, 2024

  • Hardware removal is indicated for complications such as infection, malpositioning, allergic reactions, and soft tissue issues.
  • Elective removal in asymptomatic patients or those with trauma-related symptoms requires thorough risk-benefit analysis, considering the initial injury pattern.
  • Hardware removal can be challenging and carries risks of severe complications.
  • Conclusions:

    • Strict criteria are essential for deciding on pelvic ring hardware removal.
    • Careful consideration of potential complications and patient-specific factors is crucial before hardware removal.
    • Hardware removal should only be performed when benefits clearly outweigh the risks and potential complications.