Clinical usefulness of 3-dimensional computerized tomographic renal angiography to detect transplant renal artery
1Division of Nephrology, Department of Internal Medicine, Seoul St Mary's Hospital, College of Medicine, The Catholic University of Korea, Seoul, Korea.
Objective:
The aim of this study was to evaluate whether 3-dimensional computerized tomographic angiography (3D-CTA) is useful to detect transplant renal artery stenosis (TRAS).
Methods:
Fourteen patients with clinically suspected TRAS underwent color Doppler ultrasonography (CDU) and 3D-CTA before renal angiography. We compared 3D-CTA and CDU for accuracy based on the results of renal angiography. The safety of 3D-CTA was investigated by measuring the estimated glomerular filtration rate (eGFR) before and after the 3D-CTA examination.
Results:
The 10 men and 4 women who participated in this study showed a mean eGFR of 75 mL/min/1.73 m(2) (range 60-94). Of these, 9 patients were diagnosed with TRAS. 3D-CTA detected stenoses in all 9 patients, but CDU failed to detect it in 3, including, 2 with end-to-side arterial anastomoses, which may be more challenging to detect compared with end-to-end anastomoses. The stenotic area in 3D-CTA was similar to that detected by renal angiography (70 ± 12 vs 68 ± 11). The eGFR did not differ significantly before versus after the 3D-CTA examination; 72 ± 13 vs 69 ± 14 mL/min/1.73 m(2).
Conclusions:
3D-CTA was an effective safe method to detect renal artery stenosis among transplant recipients with an eGFR >60 mL/min/1.73 m(2).