Related Experiment Video
Updated: May 23, 2026

Integrated Compensatory Responses in a Human Model of Hemorrhage
Published on: November 20, 2016
The haemodynamic response to pre-hospital RSI in injured patients
Z B Perkins1, M Gunning, J Crilly
1Kent, Surrey and Sussex Air Ambulance Trust, Kent, UK. zaneperkins@gmail.com
Background:
Laryngoscopy and tracheal intubation provoke a marked sympathetic response, potentially harmful in patients with cerebral or cardiovascular pathology or haemorrhage. Standard pre-hospital rapid sequence induction of anaesthesia (RSI) does not incorporate agents that attenuate this response. It is not known if a clinically significant response occurs following pre-hospital RSI or what proportion of injured patients requiring the intervention are potentially at risk in this setting.
Methods:
We performed a retrospective analysis of 115 consecutive pre-hospital RSI's performed on trauma patients in a physician-led Helicopter Emergency Medical Service. Primary outcome was the acute haemodynamic response to the procedure. A clinically significant response was defined as a greater than 20% change from baseline recordings during laryngoscopy and intubation.
Results:
Laryngoscopy and intubation provoked a hypertensive response in 79% of cases. Almost one-in-ten patients experienced a greater than 100% increase in mean arterial pressure (MAP) and/or systolic blood pressure (SBP). The mean (95% CI) increase in SBP was 41(31-51) mmHg and MAP was 30(23-37) mmHg. Conditions leaving the patient vulnerable to secondary injury from a hypertensive response were common.
Conclusions:
Laryngoscopy and tracheal intubation, following a standard pre-hospital RSI, commonly induced a clinically significant hypertensive response in the trauma patients studied. We believe that, although this technique is effective in securing the pre-hospital trauma airway, it is poor at attenuating adverse physiological effects that may be detrimental in this patient group.