Magnetic Resonance Imaging Quantification of Pulmonary Perfusion using Calibrated Arterial Spin Labeling
Published on: May 30, 2011
Visual assessment of magnetic resonance imaging perfusion lesions in a large patient group
S Siemonsen1, T Fitting, G Thomalla
1Department of Diagnostic and Interventional Neuroradiology, University Medical Center Hamburg-Eppendorf, Germany. s.siemonsen@uke.uni-hamburg.de
Purpose:
Few magnetic resonance imaging (MRI) studies of stroke have evaluated the value of visual assessment of perfusion/diffusion mismatch, which is crucial for routine application. In this study an attempt was made to visually assess perfusion lesions resembling the acute clinical situation and identify parameters with the highest interobserver reliability when used to define a perfusion/diffusion mismatch and the highest accuracy for prediction of infarct growth.
Methods:
Magnetic resonance imaging was performed within 6 h of symptom onset and again 1-11 days thereafter in 86 consecutive stroke patients who received intravenous thrombolytic therapy. The MRI protocol included diffusion-weighted imaging apparent diffusion coefficient (DWI/ADC), fluid-attenuated inversion recovery (FLAIR) and perfusion imaging (PI). Maps for different perfusion parameters, e.g. cerebral blood volume (CBV), cerebral blood flow (CBF), mean transit time (MTT) and time to peak (TTP) were calculated. Areas of perfusion deficits of all perfusion parameters were visually compared to corresponding ADCs and final infarct size by two independent observers.
Results:
The final infarct size was overestimated by TTP (in 81/83 patients by raters 1 and 2, respectively), MTT (82/83) and CBF (65/74) lesions. The ADC lesions were rated smaller than the final infarct size in 43/38 cases by raters 1 and 2 and the CBV decrease was rated to underestimate final infarct size in 40/31 cases. The only significantly increased OR of 3.883 (95 % CI 1.466-10.819, p = 0.004, rater 1)/5.142 (95 % CI 1.828-15.142, p = 0.001, rater 2) for predicting infarct growth was observed for the presence of a CBV > ADC mismatch, which also showed the highest kappa value of 0.407.
Conclusions:
All mismatch patterns were prone to high interrater variability when assessed under conditions resembling the clinical setting. Of all tested mismatch patterns the CBV > ADC mismatch was the strongest predictor of lesion growth while visual assessment of TTP and CBF generally resulted in an overestimation of infarct sizes and the presence of a TTP > ADC or CBF > ADC mismatch was not significantly predictive for lesion growth. Visual inspection of these most commonly used mismatch patterns has a low value for the prediction of infarct growth and thus the estimation of the penumbra in ischemic stroke patients.
Insights
Visual assessment of perfusion/diffusion mismatch in stroke is unreliable. Cerebral blood volume (CBV) > apparent diffusion coefficient (ADC) mismatch best predicts infarct growth, but overall visual inspection has low value for predicting lesion expansion.
Area of Science:
- Neurology
- Radiology
- Medical Imaging
Background:
- Magnetic resonance imaging (MRI) is vital for stroke assessment.
- Perfusion/diffusion mismatch is crucial for understanding acute stroke.
- Visual assessment of mismatch requires further evaluation for clinical utility.
Purpose of the Study:
- To evaluate the reliability of visual assessment of perfusion/diffusion mismatch in stroke.
- To identify MRI parameters with the highest interobserver reliability for mismatch definition.
- To determine the accuracy of mismatch patterns in predicting infarct growth.
Main Methods:
- 86 stroke patients underwent MRI within 6 hours of symptom onset.
- MRI included diffusion-weighted imaging (DWI/ADC) and perfusion imaging (PI) with CBV, CBF, MTT, TTP parameters.
- Two independent observers visually compared perfusion deficits to ADC and final infarct size.
Main Results:
- Time to peak (TTP) and mean transit time (MTT) generally overestimated final infarct size.
- Cerebral blood volume (CBV) > apparent diffusion coefficient (ADC) mismatch was the strongest predictor of infarct growth (OR 3.88-5.14).
- Interobserver variability was high for most mismatch patterns, with TTP > ADC and CBF > ADC mismatches not predicting growth.
Conclusions:
- Visual assessment of perfusion/diffusion mismatch patterns in acute stroke has limited value for predicting infarct growth.
- Cerebral blood volume (CBV) > apparent diffusion coefficient (ADC) mismatch shows the most promise but requires further validation.
- High interrater variability underscores the need for standardized quantitative methods over visual inspection.
Related Concept Videos
Magnetic Resonance Imaging
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this principle...
Radiological Investigation II: MRI and Ventilation Perfusion Scan
Magnetic Resonance Imaging (MRI) and Ventilation Perfusion Scans are two radiological investigations that offer detailed diagnostic images of the body, particularly lung structures.
MRI
MRI uses magnetic fields and radiofrequency signals to distinguish between normal and abnormal tissues. This technology provides a more detailed diagnostic image than CT scans, enabling it to characterize pulmonary nodules, stage bronchogenic carcinoma, and evaluate inflammatory activity in...
Imaging Studies for Cardiovascular System IV: CMRI
Imaging Studies IV: Magnetic Resonance Imaging
Imaging Studies VII: Vascular Imaging