Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Experiment Video

Updated: May 23, 2026

Iris Fixation via External Pentagram Suturing
05:22

Iris Fixation via External Pentagram Suturing

Published on: May 5, 2022

Visual changes after encircling band removal.

Xin Liao1, Xiao-qiang Liu, Hui Li

  • 1Department of Ophthalmology, Shanghai Tenth People's Hospital, Tongji University, Shanghai, China.

Ophthalmologica. Journal International D'Ophtalmologie. International Journal of Ophthalmology. Zeitschrift Fur Augenheilkunde
|April 11, 2012
PubMed
Summary
This summary is machine-generated.

Related Concept Videos

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

The value of myocardial perfusion CZT-SPECT in the assessment of coronary microvascular dysfunction in INOCA patients: a comparative study with caIMR.

The international journal of cardiovascular imaging·2026
Same author

Ailanthone alleviates septic cardiomyopathy by attenuating MYST histone acetyltransferase 1 (MOF)-mediated H4K16 lactylation-driven inflammation.

British journal of pharmacology·2026
Same author

HLA-E single-chain trimer shields gene-edited allogeneic CAR T cells from NK cell attack.

Blood advances·2026
Same author

2'-O-Methylation maintains ribosome structural and translation integrity.

Molecular cell·2026
Same author

Study on the strength and erosion resistance of soil-amended substrates for rock slopes in Fugu County.

Scientific reports·2026
Same author

A systematic assessment of regional landslide risk under typhoon rainfall: a case study of Taishun, Zhejiang, China in September 2016.

Scientific reports·2026

Removing scleral encircling bands improved visual acuity and reduced astigmatism. This safe procedure also enhanced macular retinal light sensitivity, suggesting better visual outcomes post-surgery.

Area of Science:

  • Ophthalmology
  • Retinal Surgery

Background:

  • Scleral encircling bands are used in retinal detachment surgery.
  • The long-term effects of these bands on visual function are not fully understood.

Purpose of the Study:

  • To investigate visual changes in patients after the removal of scleral encircling bands.
  • To evaluate the safety and feasibility of removing scleral encircling bands.

Main Methods:

  • A study involving 40 patients (40 eyes) undergoing scleral band removal.
  • Control group included fellow eyes and patients with non-removed bands.
  • Evaluations included visual acuity, intraocular pressure, axial length, microperimetry, and corneal topography.

Main Results:

  • Significant improvement in best-corrected visual acuity and astigmatism at 6 months post-removal (p < 0.05).

More Related Videos

Full-Circle Cauterization of Limbal Vascular Plexus for Surgically Induced Glaucoma in Rodents
10:10

Full-Circle Cauterization of Limbal Vascular Plexus for Surgically Induced Glaucoma in Rodents

Published on: February 15, 2022

Anterior Segment Organ Culture Platform for Tracking Open Globe Injuries and Therapeutic Performance
07:27

Anterior Segment Organ Culture Platform for Tracking Open Globe Injuries and Therapeutic Performance

Published on: August 25, 2021

Related Experiment Videos

Last Updated: May 23, 2026

Iris Fixation via External Pentagram Suturing
05:22

Iris Fixation via External Pentagram Suturing

Published on: May 5, 2022

Full-Circle Cauterization of Limbal Vascular Plexus for Surgically Induced Glaucoma in Rodents
10:10

Full-Circle Cauterization of Limbal Vascular Plexus for Surgically Induced Glaucoma in Rodents

Published on: February 15, 2022

Anterior Segment Organ Culture Platform for Tracking Open Globe Injuries and Therapeutic Performance
07:27

Anterior Segment Organ Culture Platform for Tracking Open Globe Injuries and Therapeutic Performance

Published on: August 25, 2021

  • Enhanced fixation stability and macular retinal light sensitivity observed.
  • No significant changes in axial length were noted.
  • Conclusions:

    • Scleral band removal may lead to improved visual outcomes by reducing corneal astigmatism and enhancing macular sensitivity.
    • The procedure is deemed safe, simple, and feasible.