Access techniques, platforms and instruments for LESS

Julien Guillotreau1, Sebastien Crouzet, Georges Pascal Haber

  • 1Glickman Urological and Kidney Institute, Cleveland Clinic, Cleveland, OH 44195, USA.

Abstract

Related Concept Videos

Derivatives of Inverse Trigonometric Functions01:30

Derivatives of Inverse Trigonometric Functions

A ship tracking an approaching aircraft relies on geometric measurements to find out the aircraft’s position relative to the observer. By measuring the slant distance to the aircraft and the angle of elevation, the horizontal and vertical components of the distance can be obtained using trigonometric relationships. This geometric approach provides a basis for analyzing how the observed angle changes as the aircraft moves closer to the ship.To examine the mathematical behavior of the angle of...
Non-Oral Extravascular Drug Absorption Routes01:15

Non-Oral Extravascular Drug Absorption Routes

Non-oral extravascular routes, which encompass sublingual, buccal, topical, intramuscular, and inhalation methods, primarily utilize passive diffusion to transport drugs into the systemic circulation. The absorption rates and effectiveness of these routes depend on the drug's physicochemical properties, as well as the patient's anatomical and pathophysiological state.
Lipophilic drugs that are stable at salivary pH (6) and exhibit minimal binding to the oral mucosa are absorbed more effectively...
Guidelines and Strategies for Safe Computer Charting01:18

Guidelines and Strategies for Safe Computer Charting

The guidelines and strategies provided by the American Nurses Association (ANA) and the Canadian Nurses Association (CNA) offer essential principles for ensuring safe and secure computer charting systems in healthcare settings. Let's break down each recommendation:
Maintain Confidentiality and Security:
Inductively Coupled Plasma Atomic Emission Spectroscopy: Instrumentation01:26

Inductively Coupled Plasma Atomic Emission Spectroscopy: Instrumentation

Inductively coupled plasma (ICP) is the common plasma source used in atomic emission spectroscopy (AES), a technique that detects and analyzes various elements in a sample. This method is often called inductively coupled plasma atomic emission spectroscopy (ICP-AES).
There are three main types of inductively coupled plasma atomic emission spectroscopy  (ICP-AES) instruments: sequential, simultaneous multichannel, and Fourier transform instruments, with the latter being less commonly used.
Capillary Electrophoresis: Instrumentation01:20

Capillary Electrophoresis: Instrumentation

Capillary electrophoresis instrumentation typically consists of several key components. A high-voltage power supply generates the electric field necessary for the separation by connecting to an anode (the positively charged electrode) and a cathode (the negatively charged electrode) located in buffer reservoirs at each end of the capillary tube. The system includes a sample vial, a fused silica capillary tube coated with polyimide for mechanical strength through which the sample components...
Atomic Absorption Spectroscopy: Instrumentation01:22

Atomic Absorption Spectroscopy: Instrumentation

An atomic absorption spectrophotometer (AAS) comprises several components: a radiation source, an atomizer, a monochromator, and a detector. The radiation source can be a hollow-cathode lamp (HCL) or an electrodeless-discharge lamp (EDL), both of which provide a narrow emission line of the required wavelength. However, some instruments use continuum sources and high-resolution monochromators to achieve a narrow range of radiation.
The atomizer used in AAS can be either a flame atomizer or an...