Related Experiment Video
Updated: May 23, 2026

Pipeline for Planning and Execution of Transcranial Ultrasound Neuromodulation Experiments in Humans
Published on: June 28, 2024
Extending patient simulation: a novel prototype to produce tympanic thermal output
Michelle A Kelly1, John Robert Forbes, Christopher Carpenter
1Faculty of Nursing, Midwifery and Health, University of Technology, Sydney, NSW 2007, Australia. Michelle.Kelly@uts.edu.au
Introduction:
Despite technologic advances in task trainers and manikins, there persists an inability to replicate key clinical skills as would occur in clinical settings. This report provides details of a project to develop a functional and reliable tympanic thermal simulator prototype that could be embedded into the ear of a manikin to enable tympanic thermometers to be used during simulation encounters.
Methods:
A simple electrical circuit was built using (i) a standard 9-V battery, (ii) a switch, (iii) 5 × 62-Ω resistors in parallel for circuit stability, (iv) a 62-Ω resistor in parallel with (v) a 1-kΩ potentiometer to vary the infrared light-emitting diode (IRLED) intensity, and (vi) 2 IRLEDs. After confirming reliability of circuit performance, the IRLEDs were implanted into the ear of a manikin. Over 3 consecutive days, 3033 samples were recorded simulating a range of human body temperatures, controlled by altering current flow.
Results:
Initial testing of the thermal simulator prototype indicates that a range of human temperatures (34.0°C-41.9°C) can be generated using high-intensity IRLEDs. Although, at higher applied current levels, the variation in measured temperature was larger (2.4°C) than at lower applied currents (0.2°C), reasonably precise temperatures were achieved.
Conclusions:
Testing and reporting initial prototype results are an important first step in developing and refining a useful product to enhance manikin capabilities associated with patient physical assessment in the simulation setting. Despite the undesired variation, the current design could still be used for teaching purposes in educational settings. Retrieving tympanic temperatures during "patient assessment" of the simulator benefits nursing, midwifery, and other health care students by enabling authentic practice. Further development of this prototype is required to improve the reliability, precision, and accuracy of the device.
Related Concept Videos
Assessing Body Temperature - Tympanic membrane
Step 1: Begin by practicing good hand hygiene to prevent the transmission of microorganisms.
Step 2: Turn on the thermometer and wait until the ready sign appears on the screen to ensure accurate measurement.
Step 3: Slide the probe cover in place to prevent cross-contamination.
Step 4: Instruct the patient to tilt their head to the side for comfort and check for cerumen...
Thermosensation
Thermal expansion and Thermal stress: Problem Solving
To solve the problem, first, identify the known and unknown quantities. The initial length (L) of the bridge is 1275 m, the coefficient of linear expansion (α) for steel is 12 x 10-6/°C, and the change in temperature (ΔT) is 55 °C.
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's forehead...
Assessing Body Temperature - Oral
Step 1:
Start by practicing proper hand hygiene to prevent the spread of microorganisms.
Step 2:
Take the thermometer out of the charging unit, switch it on, and wait for the ready sign.
Step 3:
Gently slide the probe cover until a click is heard. This simple action prevents cross-contamination and ensures the correct placement of the probe cover.
Step 4:
Instruct the patient to open their mouth and place...