Related Experiment Video
Updated: May 23, 2026

A High-throughput Method for Measurement of Glomerular Filtration Rate in Conscious Mice
Published on: May 10, 2013
Accuracy of a GFR estimating equation over time in people with a wide range of kidney function
Smita Padala1, Hocine Tighiouart, Lesley A Inker
1Tufts Medical Center, Boston, MA 02111, USA.
Background:
Change in glomerular filtration rate (GFR) is important for clinical decision making. GFR estimates from serum creatinine level provide an unbiased but imprecise estimate of GFR at single time points. However, the accuracy of estimated GFR over time is not well known.
Study Design:
Longitudinal study of diagnostic test accuracy.
Settings & Participants:
4 clinical trials with longitudinal measurements of GFR and serum creatinine on the same day, including individuals with and without kidney disease with a wide range of kidney function, diverse racial backgrounds, and varied clinical characteristics.
Index Test:
GFR estimated using the Chronic Kidney Disease Epidemiology Collaboration (CKD-EPI) equation.
Reference Test:
GFR measured using urinary clearance of (125)I-iothalamate.
Results:
Data included 19,735 GFR measurements in 3,531 participants during a mean follow-up of 2.6 years. Mean values at baseline for measured and estimated GFR and error (measured GFR - estimated GFR) were 73.1 (95% CI, 71.6 to 74.5), 72.7 (95% CI, 71.5 to 74.0), and 0.14 (95% CI, -0.35 to 0.63) mL/min/1.73 m(2), respectively. Mean rates of change in measured and estimated GFR and error were -2.3 (95% CI, -2.4 to -2.1), -2.2 (95% CI, -2.4 to -2.1), and -0.09 (95% CI, -0.24 to 0.05) mL/min/1.73 m(2) per year (P < 0.001, P < 0.001, and P = 0.2, respectively). Variability (ie, standard deviation) among participants in rate of change in measured GFR, estimated GFR, and error was 4.3, 3.4, and 3.3 mL/min/1.73 m(2) per year, respectively. Only 15% of participants had a rate of change in error >3 mL/min/1.73 m(2) per year, and only 2% had a rate of change in error >5% per year.
Limitations:
Participants' characteristics were not available over time.
Conclusion:
The accuracy of GFR estimates did not change over time. Clinicians should interpret changes in estimated GFR over time as reflecting changes in measured GFR rather than changes in errors in the GFR estimates in most individuals.
Related Concept Videos
Drug Dosing in Renal Diseases: Estimation of Glomerular Filtration Rate Based on Serum Creatinine Concentration
Drug Dosing in Renal Diseases: Measurement of Glomerular Filtration Rate
Drug Dosing in Renal Diseases: Measurement of Serum Creatinine Concentration and Clearance
Factors Affecting Renal Clearance: Renal Impairment
One condition associated with renal failure is uremia. Uremia is characterized by impaired glomerular filtration and fluid accumulation in the body. This condition hinders the renal clearance of drugs, resulting in drug accumulation and potential...
Pharmacokinetics in Geriatric Patients: Effect of Age on Drug Excretion
Renal Clearance
Renal clearance refers to the volume of plasma cleared of a specific substance, such as creatinine, per unit of time. To measure clearance, urine samples are collected over a 24-hour period during each bladder voiding, followed by a single blood sample at the...