Julia Fruehwald-Pallamar1, Marion Jantsch, Katja Pinker
1Department of Radiology, Division of Molecular and Gender Imaging, Medical University of Vienna,Waehringer Guertel 18-20, 1090 Vienna, Austria. Julia.fruehwald-pallamar@meduniwien.ac.at
Purpose:
The purpose of our study was to demonstrate the feasibility of sending uncompressed digital mammograms in a teleradiologic setting without loss of information by comparing image quality, lesion detection, and BI-RADS assessment.
Materials And Methods:
CDMAM phantoms were sent bidirectionally to two hospitals via the network. For the clinical aspect of the study, 200 patients were selected based on the BI-RAD system: 50% BI-RADS I and II; and 50% BI-RADS IV and V. Two hundred digital mammograms (800 views) were sent to two different institutions via a teleradiology network. Three readers evaluated those 200 mammography studies at institution 1 where the images originated, and in the two other institutions (institutions 2 and 3) where the images were sent. The readers assessed image quality, lesion detection, and BI-RADS classification.
Results:
Automatic readout showed that CDMAM image quality was identical before and after transmission. The image quality of the 200 studies (total 600 mammograms) was rated as very good or good in 90-97% before and after transmission. Depending on the institution and the reader, only 2.5-9.5% of all studies were rated as poor. The congruence of the readers with respect to the final BI-RADS assessment ranged from 90% and 91% at institution 1 vs. institution 2, and from 86% to 92% at institution 1 vs. institution 3. The agreement was even higher for conformity of content (BI-RADS I or II and BI-RADS IV or V). Reader agreement in the three different institutions with regard to the detection of masses and calcifications, as well as BI-RADS classification, was very good (κ: 0.775-0.884). Results for interreader agreement were similar.
Conclusion:
Uncompressed digital mammograms can be transmitted to different institutions with different workstations, without loss of information. The transmission process does not significantly influence image quality, lesion detection, or BI-RADS rating.
More Related Videos
Related Concept Videos
Radiological Investigation I: X-ray and CT
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies III: Computed Tomography
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Imaging Studies II: Ultrasonography
Radiological Investigation II: MRI and Ventilation Perfusion Scan
Magnetic Resonance Imaging (MRI) and Ventilation Perfusion Scans are two radiological investigations that offer detailed diagnostic images of the body, particularly lung structures.
MRI
MRI uses magnetic fields and radiofrequency signals to distinguish between normal and abnormal tissues. This technology provides a more detailed diagnostic image than CT scans, enabling it to characterize pulmonary nodules, stage bronchogenic carcinoma, and evaluate inflammatory activity in...