Related Experiment Video
Updated: May 23, 2026

Ion Exchange Chromatography (IEX) Coupled to Multi-angle Light Scattering (MALS) for Protein Separation and Characterization
Published on: April 5, 2019
Separation and detection of bis-maleimide-polyethylene glycol and mono-maleimide-polyethylene glycol by
Liya Tang1, Freneil Jariwala, Mark Bolgar
1Bristol-Myers Squibb Co., Analytical and Bioanalytical Development, 1 Squibb Drive, New Brunswick, NJ 08903, USA. liya.tang@bms.com
Abstract:
Monofunctional maleimide polyethylene glycol (mono-mal-PEG) with average molecular weight up to 40 kDa can be used as a raw material for the PEGylation of therapeutic proteins. A possible impurity in this raw material which needs to be controlled is the bisfunctional maleimide-PEG, which has a similar average molecular weight to mono-mal-PEG. Chromatographic separation and detection of low level bis-mal-PEG in mono-mal-PEG presents a major challenge because of the polydispersity of the analytes and the minor difference between the desired mono-mal-PEG and the bis-mal-PEG impurity. In this study, linear mal-PEGs were first derivatized with a specially designed cys-peptide containing a UV chromophore and multiple ionizable sites. Separations were then carried out by reversed-phase HPLC with UV detection at 360 nm. Mono-mal-PEG and bis-mal-PEG were well resolved using a Gemini C18 column with an aqueous-acetonitrile mobile phase. Retention times increased as PEG molecular weight increased from 10 kDa to 40 kDa, while selectivities decreased as PEG molecular weight increased. Results from systematically designed studies for optimization of critical parameters including gradient slope, column temperature, and acidic modifier in the mobile phase led to the selection of the final separation conditions. The developed method conditions were specific, accurate, and sensitive for detecting bis-mal-PEG as an impurity in mono-mal-PEG with limit of quantitation of 0.2% and may be used to assess the quality of mono-mal-PEG as a raw material for protein PEGylation.
More Related Videos
11:18Isolation and Preparation of Bacterial Cell Walls for Compositional Analysis by Ultra Performance Liquid Chromatography
Published on: January 15, 2014
09:34Improved Polymerase Chain Reaction-restriction Fragment Length Polymorphism Genotyping of Toxic Pufferfish by Liquid Chromatography/Mass Spectrometry
Published on: September 20, 2016
Related Concept Videos
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process:
Ion-Exchange Chromatography
Capillary Electrophoresis: Applications
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...
High-Performance Liquid Chromatography: Elution Process
Size-Exclusion Chromatography
Silica particles offer advantages such as rigidity,...
Types Of Column Chromatography
Gel Filtration Chromatography
When the...