Related Experiment Video
Updated: May 23, 2026

Surgical Placement of Catheters for Long-term Cardiovascular Exercise Testing in Swine
Published on: February 9, 2016
Relationship between pump speed and exercise capacity during HeartMate II left ventricular assist device support:
Mumin R Noor1, Christopher Bowles, Nicholas R Banner
1Heart Failure Care Group, Royal Brompton and Harefield NHS Foundation Trust, Harefield Hospital, Harefield, Middlesex UB9 6JH, UK.
Aims:
Patients treated with a Thoratec HeartMate II left ventricular assist device (LVAD) are supported at a fixed pump speed. It is uncertain whether pump speed has a significant effect on exercise capacity. We investigated the relationship between pump speed and exercise capacity and the influence of residual LV function
Methods And Results:
We exercised 30 patients 6 months after HeartMate II implantation at clinical pump speed (typically 9000 r.p.m.) and again at the lowest speed available (6000 r.p.m.). Overall, peak oxygen uptake (pkVO(2)) positively correlated with LV ejection fraction (LVEF) both at the clinical pump speed (r = 0.41, P = 0.03) and after pump speed reduction (r = 0.50, P = 0.01). We divided the patients into two groups; those with higher LVEF (LVEF ≥40%) and those with lower LVEF (LVEF <40%) at the time of exercise testing. The response to speed change was different between the two groups. In the higher LVEF group, the impact of LVAD pump speed reduction was minimal (pkVO(2) 21.4 ± 4.8 mL/kg/min vs. 20.8 ± 5.5 mL/kg/min, P = 0.38). In the lower LVEF group, the pkVO(2) was lower at both speeds; 17.2 ± 5.3 and 14.7 ± 5.9 mL/kg/min, respectively. In the lower LVEF group, the pkVO(2) decreased by 2.5 mL/kg/min (P = 0.02) with speed reduction.
Conclusions:
HeartMate II patients with lower residual LV function had a lower pkVO(2) and were more sensitive to pump speed reduction. This suggests that modulation of LVAD speed during exercise could be of benefit to this group of patients.
Related Concept Videos
Cardiac Output II: Effect of Stroke Volume on Cardiac Output
Preload
Preload refers to the initial elongation of the cardiac myocytes before contraction and is related to the volume of blood filling the heart at the end of diastole, or end-diastolic volume. The...
Cardiac Output I:Effect of Heart Rate on Cardiac Output
Cardiac output (CO) refers to the total amount of blood ejected by one of the ventricles in liters per minute (L/min). In a resting adult, CO ranges from 5 to 6 L/min, adjusting according to the body's metabolic requirements.
Effect of Heart Rate on Cardiac Output
Cardiac output adapts to metabolic demands during stress, physical activity, or illness. The autonomic nervous system regulates heart rate via the sinoatrial node. The parasympathetic nervous system decreases heart rate...
Exercise and Cardiac Output
Sustained exercise increases the muscles' oxygen demand, which can be met...
Pathophysiology of Cardiac Performance
Imbalances in Cardiac Output
CHF can occur due to the failure of either side of the heart. Left-side failure leads to pulmonary congestion—the right side continues to send blood...
Cardiac Output and Stroke Volume
In an average resting adult male, the typical cardiac output averages...