Evaluation of microbubbles as contrast agents for ultrasonography and magnetic resonance imaging
Ling Li1, Qiang Wei, Hong-Bo Li
1Jiangsu Key Laboratory of Molecular Imaging and Functional Imaging, Department of Radiology, Zhong-Da Hospital, Medical School of Southeast University, Nanjing, China.
Background:
Microbubbles (MBs) can serve as an ultrasound contrast agent, and has the potential for magnetic resonance imaging (MRI). Due to the relatively low effect of MBs on MRI, it is necessary to develop new MBs that are more suitable for MRI. In this study, we evaluate the properties of SonoVue® and custom-made Fe(3)O(4)-nanoparticle-embedded microbubbles (Fe(3)O(4)-MBs) in terms of contrast agents for ultrsonography (US) and MRI.
Methodology/Principal Findings:
A total of 20 HepG2 subcutaneous-tumor-bearing nude mice were randomly assigned to 2 groups (i.e., n = 10 mice each group), one for US test and the other for MRI test. Within each group, two tests were performed for each mouse. The contrast agent for the first test is SonoVue®, and the second is Fe(3)O(4)-MBs. US was performed using a Technos(MPX) US system (Esaote, Italy) with a contrast-tuned imaging (CnTI™) mode. MRI was performed using a 7.0T Micro-MRI (PharmaScan, Bruker Biospin GmbH, Germany) with an EPI-T(2)* sequence. The data of signal-to-noise ratio (SNR) from the region-of-interest of each US and MR image was calculated by ImageJ (National Institute of Health, USA). In group 1, enhancement of SonoVue® was significantly higher than Fe(3)O(4)-MBs on US (P<0.001). In group 2, negative enhancement of Fe(3)O(4)-MBs was significantly higher than SonoVue® on MRI (P<0.001). The time to peak showed no significant differences between US and MRI, both of which used the same MBs (P>0.05). The SNR analysis of the enhancement process reveals a strong negative correlation in both cases (i.e., SonoVue® r = -0.733, Fe(3)O(4)-MBs r = -0.903, with P<0.05).
Conclusions:
It might be important to change the Fe(3)O(4)-MBs' shell structure and/or the imagining strategy of US to improve the imaging quality of Fe(3)O(4)-MBs on US. As an intriguing prospect that can be detected by US and MRI, MBs are worthy of further study.
Related Concept Videos
Imaging Studies for Cardiovascular System II:Types of Echocardiography
Types of Echocardiography
Transthoracic Echocardiography (TTE)
TTE is the most common type of echocardiogram which involves placing a transducer on the patient's chest, emitting sound waves to create heart images. TTE is invaluable for evaluating the heart's size, structure, and motion, making it particularly useful for diagnosing...
Magnetic Resonance Imaging
Imaging Studies IV: Magnetic Resonance Imaging
Ultrasonography
During an ultrasonography procedure, a handheld device called a...
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Imaging Studies for Cardiovascular System IV: CMRI