Related Concept Videos

Computed Tomography01:10

Computed Tomography

Tomography refers to imaging by sections. Computed tomography (CT) is a non-invasive imaging technique that uses computers to analyze several cross-sectional X-rays to reveal minute details about structures in the body.
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies III: Computed Tomography01:27

Imaging Studies III: Computed Tomography

DefinitionComputed Tomography (CT) of the genitourinary (GU) tract is a non-invasive imaging modality that utilizes X-rays and computer processing to generate detailed cross-sectional images of the urinary system, encompassing the kidneys, ureters, bladder, and adjacent structures such as the adrenal glands.PurposeCT scans of the GU tract serve several diagnostic and therapeutic purposes, including:Diagnosis of Urinary Tract Diseases: Detects kidney stones, tumors, cysts, and congenital...
Positron Emission Tomography01:29

Positron Emission Tomography

Positron emission tomography (PET) is a medical imaging technique involving radiopharmaceuticals — substances that emit short-lived radiation. Although the first PET scanner was introduced in 1961, it took 15 more years before radiopharmaceuticals were combined with the technique and revolutionized its potential.
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body being...
Electron Microscope Tomography and Single-particle Reconstruction01:07

Electron Microscope Tomography and Single-particle Reconstruction

Transmission electron microscopy (TEM) can be used to determine the 3D structure of biological samples with the help of techniques such as electron microscope tomography and single-particle reconstruction. While single-particle reconstruction can examine macromolecules and macromolecular complexes in vitro conditions only, tomography permits the study of cell components or small cells in vivo.
Electron Tomography
Electron tomography can be performed either in TEM or STEM (scanning transmission...
Imaging Studies I: CT and MRI01:14

Imaging Studies I: CT and MRI

Introduction: MRI and CT scans are crucial advancements in medical imaging techniques, playing a vital role in diagnosing conditions related to the gastrointestinal (GI) system. Each scan serves distinct purposes, targets specific areas, and requires unique nursing duties.
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Imaging Studies II: Positron Emission Tomography and Scintigraphy01:25

Imaging Studies II: Positron Emission Tomography and Scintigraphy

Positron Emission Tomography (PET) is a medical imaging technique that provides crucial insights into the body's physiological functions at a molecular level. It is an indispensable resource for diagnosing, staging, and monitoring various illnesses, notably cancer, neurological disorders, and cardiovascular conditions.
Fundamental Principles of PET

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Interpretable Deep Learning for Single-Molecule Nanopore Fingerprinting Using Physics-Guided Preprocessing.

ACS sensors·2026
Same author

AI to Identify Strain-Sensitive Regions of the Optic Nerve Head Linked to Functional Loss in Glaucoma.

Investigative ophthalmology & visual science·2026
Same author

Integrated lithium niobate photonic computing circuit based on efficient and high-speed electro-optic conversion.

Nature communications·2025
Same author

Sensitivity fields and parameter estimation from dielectric objects.

Journal of the Optical Society of America. A, Optics, image science, and vision·2025
Same author

Biomechanics-Function in Glaucoma: Improved Visual Field Predictions from IOP-Induced Neural Strains.

American journal of ophthalmology·2024
Same author

Deep-prior ODEs augment fluorescence imaging with chemical sensors.

Nature communications·2024
See all related articles

Related Experiment Video

Updated: May 23, 2026

Reservoir Condition Pore-scale Imaging of Multiple Fluid Phases Using X-ray Microtomography
08:02

Reservoir Condition Pore-scale Imaging of Multiple Fluid Phases Using X-ray Microtomography

Published on: February 25, 2015

Experimental compressive phase space tomography.

Lei Tian1, Justin Lee, Se Baek Oh

  • 1Department of Mechanical Engineering, Massachusetts Institute of Technology, 77 Massachusetts Avenue, Cambridge, MA 02139, USA. lei_tian@mit.edu

Optics Express
|April 20, 2012
PubMed
Summary
This summary is machine-generated.

This study demonstrates compressive reconstruction for optical correlation functions. The new method improves mutual intensity estimates by assuming low-entropy sources, outperforming traditional techniques.

More Related Videos

Three-Dimensional Phase Resolved Functional Lung Magnetic Resonance Imaging
10:44

Three-Dimensional Phase Resolved Functional Lung Magnetic Resonance Imaging

Published on: June 21, 2024

Retrospective Cardiac Gating with A Prototype Small-Animal X-ray Computed Tomograph
05:32

Retrospective Cardiac Gating with A Prototype Small-Animal X-ray Computed Tomograph

Published on: February 21, 2025

Related Experiment Videos

Last Updated: May 23, 2026

Reservoir Condition Pore-scale Imaging of Multiple Fluid Phases Using X-ray Microtomography
08:02

Reservoir Condition Pore-scale Imaging of Multiple Fluid Phases Using X-ray Microtomography

Published on: February 25, 2015

Three-Dimensional Phase Resolved Functional Lung Magnetic Resonance Imaging
10:44

Three-Dimensional Phase Resolved Functional Lung Magnetic Resonance Imaging

Published on: June 21, 2024

Retrospective Cardiac Gating with A Prototype Small-Animal X-ray Computed Tomograph
05:32

Retrospective Cardiac Gating with A Prototype Small-Animal X-ray Computed Tomograph

Published on: February 21, 2025

Area of Science:

  • Optics
  • Quantum Optics
  • Information Theory

Background:

  • Phase space tomography estimates correlation functions from wave function evolution snapshots.
  • Traditional interferometric methods require multiple two-point correlation measurements.
  • Undersampling is a significant limitation in tomographic methods.

Purpose of the Study:

  • To experimentally demonstrate compressive reconstruction of the classical optical correlation function (mutual intensity function).
  • To validate a compressive algorithm utilizing the low-entropy source assumption.
  • To compare the performance of compressive reconstruction against traditional methods.

Main Methods:

  • Experimental implementation of phase space tomography.
  • Development and application of a compressive reconstruction algorithm.
  • Utilizing a low-entropy source assumption for algorithm design.
  • Comparison with ground-truth estimates derived from the van Cittert-Zernike theorem.

Main Results:

  • Successful experimental demonstration of compressive reconstruction for mutual intensity.
  • Substantial quantitative improvements in reconstruction accuracy were verified.
  • The compressive approach showed significant advantages over traditional methods.

Conclusions:

  • Compressive reconstruction offers a powerful approach for estimating optical correlation functions.
  • The low-entropy source assumption is physically justifiable and enhances reconstruction.
  • This technique provides a more efficient and accurate alternative to traditional interferometry.