Related Experiment Video
Updated: Feb 6, 2026

Controlled Semi-Automated Laser-Induced Injuries for Studying Spinal Cord Regeneration in Zebrafish Larvae
Published on: November 22, 2021
SPECIAL semi-LASER with lipid artifact compensation for 1H MRS at 7 T
Alexander Fuchs1, Mariska Luttje, Peter Boesiger
1Department of Information Technology and Electrical Engineering, Institute for Biomedical Engineering, University of Zurich and ETH Zurich, Zurich, Switzerland. fuchs@biomed.ee.ethz.ch
Abstract:
The measurement of full metabolic profiles at ultrahigh fields including low concentrated or fast-relaxing metabolites is usually achieved by applying short echo time sequences. One sequence beside stimulated echo acquisition mode that was proposed in this regard is spin echo full intensity-acquired localized spectroscopy. Typical problems that are still persistent for spin echo full intensity-acquired localized spectroscopy are B(1) inhomogeneities especially for signal acquisition with surface coils and chemical shift displacement artifacts due to limited B(1) amplitudes when using volume coils. In addition, strong lipid contaminations in the final spectrum can occur when only a limited number of outer volume suppression pulses is used. Therefore, an adiabatic short echo time (= 19 ms) spin echo full intensity-acquired localized spectroscopy semilocalization by adiabatic selective refocusing sequence is presented that is less sensitive to strong B(1) variations and that offers increased excitation and refocusing pulse bandwidths than regular spin echo full intensity acquired localized spectroscopy. Furthermore, the existence of the systematic lipid artifact is identified and linked to unfavorable effects due to the preinversion localization pulse. A method to control this artifact is presented and validated in both phantom and in vivo measurements. The viability of the proposed sequence was further assessed for in vivo measurements by scanning 17 volunteers using a surface coil and moreover acquiring additional volume coil measurements. The results show well-suppressed lipid artifacts, good signal-to-noise ratio, and reproducible fitting results in accordance with other published studies.
Related Concept Videos
Special Staining Techniques
Dosage Compensation
In addition to sexual development, the X chromosome has genes involved in autosomal functions such as brain development and the immune system. Therefore, males and females with distinct numbers of X chromosomes will...
Compensation Mechanisms
Respiratory Compensation
This mechanism addresses metabolic-induced pH imbalances by adjusting breathing rates. Respiratory compensation begins within minutes of detecting a pH...
What are Lipids?
Lipid Digestion
Introduction to Special Senses

