Related Experiment Video
Updated: May 23, 2026

Thinned-skull Cortical Window Technique for In Vivo Optical Coherence Tomography Imaging
Published on: November 19, 2012
Noninvasive cross-sectional imaging of incomplete crown fractures (cracks) using swept-source optical coherence
Y Nakajima1, Y Shimada, M Miyashin
1Pediatric Dentistry, Department of Orofacial Development and Function, Graduate School, Tokyo Medical and Dental University, Tokyo, Japan. nakadohs@tmd.ac.jp
Aim:
To investigate the ability of swept-source optical coherence tomography (SS-OCT) to detect incomplete crown fractures (cracks) in extracted teeth.
Methodology:
Cracks were created by subjecting 30 porcine premolars to impaction by a steel rod plunging from the occlusal tip. SS-OCT images and stereomicroscopic photographs of the surface were acquired for each specimen before and after impaction. For evaluation, the focused light beam of SS-OCT was projected from three directions on the same plane: buccal or lingual, 45° to the mesial, and 45° to the distal. Histological sections were prepared after impaction, and length and width of cracks and lamellae were evaluated using the corresponding SS-OCT image. The values were analysed using Pearson's correlation coefficient.
Results:
Through SS-OCT, cracks and lamellae were clearly detected as intensified scattering signals at the same position on the corresponding microphotographs and histological sections. Amongst the three scanning angles, the greatest lengths and widths were considered the corresponding values of SS-OCT and were used for analysis. Significant correlations regarding line length and width were observed between SS-OCT and histological sections (length: r = 0.65, P < 0.001; width: r = 0.60, P < 0.001).
Conclusions:
SS-OCT can clearly discriminate cracks, which appear as highlighted lines due to the scattering of light. The results obtained from the three scanning directions were correlated well with those of the histological sections.
More Related Videos
07:42Quasistatic Mechanical Testing for Computer-Aided Design and Manufacturing Occlusal Veneers Cemented to Milled Dentin Analog Material
Published on: December 20, 2024
07:44In vivo Structural Assessments of Ocular Disease in Rodent Models using Optical Coherence Tomography
Published on: July 24, 2020
Related Concept Videos
Imaging Studies III: Computed Tomography
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Imaging Studies for Cardiovascular System V: CT