Utility of the inversion scout sequence (TI scout) in diagnosing myocardial amyloid infiltration

Tarun Pandey1, Kedar Jambhekar, Raja Shaikh

  • 1University of Arkansas for Medical Sciences, Slot 556, 4301 West Markham, Little Rock, AR 72205, USA.

To evaluate the utility of inversion scout (TI-scout) obtained during cardiac magnetic resonance imaging (CMR) in diagnosing myocardial amyloid infiltration. A retrospective analysis of CMR exams in 39 patients (24 males, age range 29-77 years) was performed. Imaging was performed on a 1.5T system, and included steady state cine, post contrast TI-scout and delayed enhancement images. Evaluations included studies in 13 patients with myocardial amyloidosis and 26 patients without myocardial amyloidosis. To characterize abnormal nulling, the time to myocardial nulling on the TI scout was compared to the null times of the blood pool and spleen for each scan. The sensitivity and specificity of different tissue nulling abnormalities for myocardial amyloidosis were computed. The null times of tissues in 18/26 (69%) patients in the non-amyloid group followed a consistent order with the blood pool null time preceding the myocardial nulling which was equal to that of splenic nulling (Type 1 pattern). This order differed in all 13 patients with myocardial amyloidosis described as three non-mutually exclusive nulling categories: 10 patients had myocardial null time preceding or coincident with blood pool (Type 2 pattern); in 11 patients myocardial null time was non-coincident with splenic nulling (Type 3 pattern); and in 8 patients myocardial null time was non-coincident with both blood pool AND splenic nulling (Type 4 pattern). While no patient exhibited Type 4 nulling pattern in the non-amyloid group, 1/26 patient had a Type 2 and 7/26 patients had a Type 3 nulling pattern. A sensitivity of 100% was obtained when either Type 2 OR Type 3 nulling was present while a specificity of 100% was obtained when both Type 2 AND Type 3 nulling were present together (Type 4 pattern). Our study demonstrates that the pattern of nulling on the TI scout sequence CMR has potential diagnostic utility for the presence of myocardial amyloidosis. The temporal pattern of myocardial, blood pool and splenic nulling needs to be carefully evaluated on the TI scout sequence and could prove useful in other infiltrative cardiomyopathies.

Related Concept Videos

Acute Coronary Syndrome III: Diagnostic Studies01:30

Acute Coronary Syndrome III: Diagnostic Studies

Diagnosing acute coronary syndrome or ACS begins with a thorough patient history. Notable symptoms include central, crushing chest pain radiating to the left arm, neck, jaw, or back, along with shortness of breath, sweating (diaphoresis), nausea, vomiting, dizziness, and palpitations.It is crucial to note any history of cardiac illnesses and assess risk factors, including age, gender, smoking, hypertension, diabetes, hyperlipidemia, and a sedentary lifestyle.During physical examination, vital...
Myocarditis II: Clinical Features and Diagnostic Tests01:27

Myocarditis II: Clinical Features and Diagnostic Tests

Myocarditis is an inflammation of the heart muscle. The symptoms vary widely, encompassing asymptomatic presentations to severe, acute manifestations.Clinical PresentationAsymptomatic cases: In some instances, myocarditis may be asymptomatic, with the infection resolving without intervention. These cases often go undetected unless discovered incidentally through diagnostic imaging or tests conducted for other reasons.General Early Symptoms: Early symptoms of myocarditis are non-specific and can...
Imaging Studies for Cardiovascular System V: CT01:28

Imaging Studies for Cardiovascular System V: CT

Cardiac computed tomography (CT) scanning is an advanced cardiac imaging technique that utilizes CT technology, with or without intravenous (IV) contrast, to produce accurate cross-sectional virtual slices of specific areas of the heart, coronary circulation, and major blood vessels such as the aorta, pulmonary veins, and arteries. The computer processes these slices to generate three-dimensional images. Multidetector CT (MDCT) is a rapid form of CT scanning that captures multiple slices...