Related Experiment Video
Updated: May 22, 2026

Optical Coherence Tomography: Imaging Mouse Retinal Ganglion Cells In Vivo
Published on: September 22, 2017
Cone dysfunctions in retinitis pigmentosa with retinal nerve fiber layer thickening
Güngör Sobacı1, Gökhan Ozge, Fatih Ç Gündoğan
1Department of Ophthalmology, Gülhane Military Medical Academy and Medical School, Etlik, Ankara, Turkey.
Purpose:
To investigate whether or not thicker retinal nerve fiber layer (RNFL) in retinitis pigmentosa (RP) patients relates to functional abnormalities of the photoreceptors.
Methods:
Optical coherence tomography-based RNFL thickness was measured by Stratus-3™ (Zeiss, Basel, Switzerland) optical coherence tomography and electroretinogram (ERG) recordings made using the RETI-port(®) system (Roland, Wiesbaden, Germany) in 27 patients with retinitis pigmentosa and in 30 healthy subjects.
Results:
Photopic ERG b-wave amplitude, cone ERG b-wave latency, 30 Hz flicker amplitude, and 30 Hz flicker latency had significant correlations to the RNFL-temporal (r = -0.55, P = 0.004, r = 0.68, P = 0.001, r = -0.65, P = 0.001, and r = -0.52, P = 0.007, respectively). Eyes with thicker RNFL (ten eyes) differed significantly from those with thinner RNFL (eight eyes) regarding cone ERG b-wave latency values only (P = 0.001).
Conclusion:
Thicker RNFL in patients with retinitis pigmentosa may be associated with functional abnormality of the cone system.
Related Concept Videos
Diabetic Retinopathy
Photoreceptors and Visual Pathways
Anatomy of the Eyeball
The Retina
Glaucoma: Overview