Fluorescence as an analytical tool for assessing the conversion of oil into biodiesel

T A Chimenez1, K F Magalhães, A R L Caires

  • 1Grupo de Óptica Aplicada, Faculdade de Ciências Exatas e Tecnologia, Universidade Federal da Grande Dourados, CP 533, 79804-970, Dourados, MS, Brazil.

Related Concept Videos

Biofuels01:25

Biofuels

The microbial conversion of organic matter into biofuels holds potential as a renewable energy source. Among biofuel sources, microalgae are recognized as a highly efficient and adaptable feedstock for biodiesel production, owing to their rapid biomass accumulation, elevated lipid productivity, and capacity to proliferate in diverse aquatic systems, including freshwater, marine, and wastewater habitats. Unlike terrestrial crops, microalgae do not compete for land and can achieve significantly...
Flame Photometry: Lab01:16

Flame Photometry: Lab

In a flame photometer, when a solution like potassium chloride is aspirated into the flame, the solvent evaporates, leaving behind dehydrated salt. This salt dissociates into free gaseous atoms in their ground state. Some of these atoms absorb energy from the flame, leading to their excitation. The excited atoms return to the ground state, emitting photons at characteristic wavelengths. Because only electronic transitions are involved, the resulting emission lines are very narrow. The intensity...
Photoluminescence: Applications01:14

Photoluminescence: Applications

Photoluminescence offers a wide range of applications due to its inherent sensitivity and selectivity. This technique allows for both direct and indirect analyses of the analyte. Direct quantitative analysis is possible when the analyte exhibits a favorable quantum yield for fluorescence or phosphorescence. However, an indirect analysis may be feasible if the analyte is not fluorescent or phosphorescent, or if the quantum yield is unfavorable. Indirect methods include reacting the analyte with...
Fluorescence and Phosphorescence: Instrumentation01:25

Fluorescence and Phosphorescence: Instrumentation

Fluorometers and spectrofluorometers are two types of instruments used for measuring molecular fluorescence. These instruments differ in how they select excitation and emission wavelengths and the type of light sources they utilize. Fluorometers use absorption interference filters to choose excitation and emission wavelengths. The excitation source in a fluorometer is typically a low-pressure mercury vapor lamp that emits intense lines distributed throughout the ultraviolet and visible regions.