Related Experiment Video
Updated: May 22, 2026

Emission Spectroscopic Boundary Layer Investigation during Ablative Material Testing in Plasmatron
Published on: June 9, 2016
Optical Thomson scattering measurements of plasma parameters in the ablation stage of wire array Z pinches
A J Harvey-Thompson1, S V Lebedev, S Patankar
1Blackett Laboratory, Imperial College, London, SW7 2BW, United Kingdom.
Abstract:
A Thomson scattering diagnostic has been used to measure the parameters of cylindrical wire array Z pinch plasmas during the ablation phase. The scattering operates in the collective regime (α>1) allowing spatially localized measurements of the ion or electron plasma temperatures and of the plasma bulk velocity. The ablation flow is found to accelerate towards the axis reaching peak velocities of 1.2-1.3×10(7) cm/s in aluminium and ∼1×10(7) cm/s in tungsten arrays. Precursor ion temperature measurements made shortly after formation are found to correspond to the kinetic energy of the converging ablation flow.
Related Concept Videos
Inductively Coupled Plasma Atomic Emission Spectroscopy: Principle
The ions and electrons produced interact with the fluctuating magnetic field created by a water-cooled...
Inductively Coupled Plasma Atomic Emission Spectroscopy: Instrumentation
There are three main types of inductively coupled plasma atomic emission spectroscopy (ICP-AES) instruments: sequential, simultaneous multichannel, and Fourier transform instruments, with the latter being less commonly used.