Related Experiment Video
Updated: May 22, 2026

Magnetic Tweezers for the Measurement of Twist and Torque
Published on: May 19, 2014
Resonance measurement of nonlocal spin torque in a three-terminal magnetic device
Lin Xue1, Chen Wang, Yong-Tao Cui
1Cornell University, Ithaca, New York 14853, USA.
Abstract:
A pure spin current generated within a nonlocal spin valve can exert a spin-transfer torque on a nanomagnet. This nonlocal torque enables new design schemes for magnetic memory devices that do not require the application of large voltages across tunnel barriers that can suffer electrical breakdown. Here we report a quantitative measurement of this nonlocal spin torque using spin-torque-driven ferromagnetic resonance. Our measurement agrees well with the prediction of an effective circuit model for spin transport. Based on this model, we suggest strategies for optimizing the strength of nonlocal torque.
Related Concept Videos
Torque On A Current Loop In A Magnetic Field
Consider a rectangular current-carrying loop containing N turns of wire, placed in a uniform magnetic field. The net force on a current-carrying loop...
Atomic Nuclei: Magnetic Resonance
Double Resonance Techniques: Overview
Spin decoupling is usually achieved by...
Atomic Nuclei: Nuclear Relaxation Processes
Atomic Nuclei: Nuclear Spin State Overview
Spin–Spin Coupling Constant: Overview
Qualitatively, any spin plus-half nucleus polarizes the spins of its electrons to the minus-half state. Consequently, the paired electron in the hydrogen–carbon bond must have a...