Background:
Accurate assessment of right ventricular (RV) size (RVS) and RV systolic function (RVSF) is vital in the management of various conditions, but their assessment is challenging using echocardiography. The aim of this study was to determine the accuracy and interobserver concordance of qualitative and quantitative RV echocardiography.
Methods:
Fifteen readers evaluated RV function in 12 patients (360 readings) who underwent echocardiography and cardiac magnetic resonance for RV assessment. Readers qualitatively estimated RVS and RVSF as normal, mild, moderate, or severe and then reassessed quantitatively by adding RV dimensions, fractional area change, S', tricuspid annular plane systolic excursion, and RV index of myocardial performance. Cardiac magnetic resonance was used as the reference standard for grading RVS and RVSF.
Results:
Quantitative measurements increased accuracy and interreader agreement compared to qualitative assessment alone, especially in normal categories. Readers' accuracy for diagnosing normal and severe RVS increased from 38% to 78% (P = .001) and from 70% to 97% (P = .018), and readers' accuracy for diagnosing normal and mild RVSF increased from 52% to 84% (P < .001) and from 36% to 56% (P = .001). Interreader agreement for classification of the subjects as normal or abnormal improved from a κ value of 0.40 to 0.77 (fair to good agreement) for RVS and from 0.43 to 0.66 (moderate to good agreement) for RVSF.
Conclusions:
Visual estimation of RVS and RVSF is inaccurate and has wide interobserver variability. Quantitation improves accuracy and reliability, especially in distinction of normal and abnormal. The reliability of mild and moderate grades remains inadequate, and further guidance is needed for the classification of abnormal categories.
Related Concept Videos
Imaging Studies for Cardiovascular System I:Echocardiography
Indications: Echocardiography is utilized to diagnose heart failure, valve disorders, and myocardial infarction. It also assesses cardiac structures' size, shape, and motion, evaluates...
Assessment of the Cardiovascular System IV: Auscultation
Normal Heart Sounds
S1 (First Heart Sound)-
S1 is made by the closure of the mitral and tricuspid valves (atrioventricular valves), marking the beginning of systole.
S2 (Second Heart Sound)-
S2 is made by the closure of the aortic and pulmonic valves (semilunar valves), marking the end of the systole.