In vitro skin corrosion: Human skin model test - A validation study
Gajanan Rajpal Deshmukh1, Kuntrapakam Hema Kumar, Poojari Venkata Suresh Reddy
1Aptus Biosciences Private Limited, Yenugonda, Mahabubnagar 509 002, Andhra Pradesh, India.
Summary
This study validates the in vitro skin corrosion human skin model test (OECD 431) as a reliable alternative to animal testing for chemical safety assessments.
Area of Science:
- Toxicology
- Dermatology
- In Vitro Testing
Background:
- The in vivo skin corrosion/irritation test is widely used in India.
- There is a growing need for validated in vitro alternatives to animal testing.
Purpose of the Study:
- To validate the EpiSkinTM in vitro skin corrosion model test.
- To assess its suitability as an alternative to the in vivo test according to OECD Test Guideline 431.
Main Methods:
- Utilized the EpiSkinTM human skin model.
- Tested various corrosive and non-corrosive chemicals as per OECD 431 guidelines.
Main Results:
- The in vitro model accurately predicted the corrosive properties of tested chemicals.
- Results aligned with known skin corrosive classifications.
Conclusions:
- The EpiSkinTM in vitro model is a valid alternative for skin corrosion testing.
- Supports the reduction of animal testing in chemical safety evaluations.
Related Concept Videos
In vitro Mutagenesis
To learn more about the function of a gene, researchers can observe what happens when the gene is inactivated or “knocked out,” by creating genetically engineered knockout animals. Knockout mice have been particularly useful as models for human diseases such as cancer, Parkinson’s disease, and diabetes.
In Vitro Drug Dissolution: Compendial Testing Models I
Compendial dissolution methods are standardized procedures defined by pharmacopeias to evaluate the rate at which a drug dissolves in a specific medium. These methods ensure batch-to-batch consistency, enable quality control, and support the prediction of drug bioavailability. They are critical for both immediate and modified-release drug products.The apparatuses used for dissolution testing differ in their design and mechanical function, but all aim to simulate the physiological environment of...
In Vitro Drug Dissolution: Compendial Testing Models II
Various dissolution methods are utilized to assess a drug’s dissolution rate, including the flow-through cell, paddle-over-disk, cylinder, and reciprocating disk methods.The flow-through cell apparatus (USP (United States Pharmacopeia) method 4) comprises a reservoir for the dissolution medium and a pump that propels the medium through the cell containing the test sample. This method is crucial for assessing modified-release dosage forms with minimally soluble active ingredients, maintaining...