Related Experiment Video
Updated: May 22, 2026

A New Single Chamber Implantable Defibrillator with Atrial Sensing: A Practical Demonstration of Sensing and Ease of Implantation
Published on: February 28, 2012
Infections of cardiac implantable electronic devices: a retrospective multicenter observational study
George M Viola1, Leah L Awan, Luis Ostrosky-Zeichner
1From the Division of Infectious Diseases (GMV), Department of Medicine, University of Texas M. D. Anderson Cancer Center; Baylor College of Medicine (GMV, LLA, ROD); University of Texas Medical School (LOZ); Michael E. DeBakey Veterans Affairs Medical Center (ROD); and Division of Biostatistics (WC), University of Texas Health Science Center; Houston, Texas.
Abstract:
Infections of cardiac implantable electronic devices (CIED) can cause significant morbidity, mortality, and financial burden. Although staphylococcal organisms account for most infections of these cardiac devices, approximately 20% of all CIED-related infections are caused by non-Staphylococcus species. Herein we describe and compare the demographics, clinical presentation, and outcomes of Staphylococcus aureus and non-staphylococcal infections of CIED.We performed a retrospective, multicenter, observational study of patients from 4 academic hospitals in Houston between 2002 and 2009. All 80 identified non-staphylococcal CIED-related infections were matched, at a 1:1 ratio, to S. aureus infections.Although the demographics and general comorbidities in the 2 study groups were relatively similar, the S. aureus group had a higher proportion of patients with coronary artery disease, diabetes mellitus, and end-stage renal disease. Additionally, 81% of S. aureus compared with only 48.5% of the non-staphylococcal CIED-related infections were health care-associated (p < 0.001). Furthermore, when compared to non-staphylococcal infections, the S. aureus group had more indwelling intravascular foreign material (p < 0.001), more rapid clinical progression (p < 0.001), and overall worse clinical presentation (p < 0.001). However, after stratifying by clinical presentation, the mortality rates in the 2 groups were similar (p = 0.45).Since approximately one-fifth of all CIED-related infections are caused by non-staphylococcal organisms, and untimely antibiotic treatment can result in serious complications, it may be prudent to broaden empiric antimicrobial therapy to cover both Gram-positive and -negative bacteria, until the causative organism is identified.
Related Concept Videos
Endocarditis I: Introduction
Endocarditis III: Medical Management
Endocarditis II: Clinical Features of Infective Endocarditis
Healthcare Associated Infections I: Iatrogenic, Exogenic and Endogenic
HAIs significantly increase the cost of health care. Extended stays in healthcare institutions, increased disability, increased costs of medications, including specialized antibiotics, and prolonged recovery times add to the patient's expenses and the healthcare institution and funding bodies. Common...
Endocarditis IV: Nursing Management
Cardiac Catheterization III: Left Heart Catheterization